5I DELLMECO I EODD DIAPHRAGM PUMPS
1. Introduction
DELLMECO DME (Electro-Mechanical Operated Double Diaphragm Pump) is a positive-displacement pump that
transfers fluids by means of diaphragms operated by linear mechanism, which is being moved by electric motor. The casing
in contact with the fluid is made of PE conductive (R
…), PTFE conductive (Z…), Aluminium (A..), AISI 316 (S..), Cast Iron
(C..), or AISI 316L (H.., Hygienic Stainless Steel). This pump is designed for the pumping of liquids, highly viscous and
solid substance-containing media, as well as fluidizable powders.
DELLMECO DME Pumps consist of two pump housings located opposite each other. The diaphragms that separate
drive and liquid areas from side housings, include a built-in metal core which ensures an optimum service life of
diaphragm.
A linear drive, located between pump housings, converts the rotating motion of the drive machine into oscillating one
through a crank. The directly linked diaphragms are moving there and back with a constant stroke, and they never
undergo a tipping motion due to special design. With each revolution of the crank the medium contained in the pump
housing is alternatively pumped out of the housing and sucked into the opposite pump housing. When the upward motion
switches to discharge motion and vice versa, the other housing assumes the suction or discharge function. Every pump
housing has ball valves or cylindrical valves (available for DME Plastic Pumps only) on the suction and discharge sides.
These valves work independently and are available in various versions, which makes it possible to optimize the shearing
and solid substance non-sensitivity, as well as to select valve material with chemically required properties depending on
the medium.
2. For safe operation
This document contains information indispensable for maintaining safe, proper and efficient operation of this
product. In the sections below you will find a description of the duties of the DME Pump operator. For safety and legal
reasons, they must be unconditionally fulfilled. Any damage arising through neglect of the information contained in these
Operating Instructions will be the responsibility of the operators and users.
The information contained in these Operating Instructions is designed for the persons operating the DME Pump. These
persons should’ve possessed basic mechanical, electric and hydraulic knowledge.
Any person transporting, mounting, operating, maintaining, repairing, or disposing the DME Pump with equipment, must
become familiar with the complete contents of these Operating Instructions and understand it. If you fail to understand
some information in these Operating Instructions or lack some information, contact DELLMECO Ltd before starting the
respective activities.
The DME Pump operator is responsible for the permanent availability of these Operating Instructions in the course of
pump operation. Keep the Operating Instructions near the DME Pump operation. In the event that these Operating
Instructions are lost or become unusable, you can download a new copy from DELLMECO website.
Read this document carefully before using the pump particularly the "warnings and cautions". Get familiar with all
operating procedures. This document must be kept handy for future reference.
3. Warnings and cautions
The meanings of warning and caution symbols are given below. Be sure to remember their meanings.
WARNING:
ignoring
the
warning
and
operating
the
product
in
an
improper
manner
can
result
in danger of serious bodily injury or death.
CAUTION:
ignoring the warning and operating the product in an improper manner can result in danger
of personal injury or property damage.
Ø
This symbol means a
“DON’T”, and will be followed by an explanation on what you must not do.
This symbol means a
“DO”, and will be followed by an explanation on what you must do in a specified situation.
!
!
Содержание DME 15 R Series
Страница 11: ...11I DELLMECO I EODD DIAPHRAGM PUMPS 5 2 DME 40 50 R Z and DME 80 R Plastic Series Diaphragm Pump exploded view...
Страница 14: ...14 I DELLMECO I EODD DIAPHRAGM PUMPS 5 3 DME 20 25 40 A C S Metal Series Diaphragm Pump exploded view...
Страница 15: ...15I DELLMECO I EODD DIAPHRAGM PUMPS 5 4 DME 50 A C S Metal Series Diaphragm Pump exploded view...
Страница 16: ...16 I DELLMECO I EODD DIAPHRAGM PUMPS 5 5 DME 80 A B Metal Series Diaphragm Pump exploded view...
Страница 17: ...17I DELLMECO I EODD DIAPHRAGM PUMPS 5 6 DME 80 S Metal Series Diaphragm Pump exploded view...
Страница 20: ...20 I DELLMECO I EODD DIAPHRAGM PUMPS 5 7 DME 25 40 50 H Hygienic Series Diaphragm Pump exploded view...
Страница 21: ...21I DELLMECO I EODD DIAPHRAGM PUMPS 5 8 DME 65 H Hygienic Series Diaphragm Pump exploded view...
Страница 22: ...22 I DELLMECO I EODD DIAPHRAGM PUMPS 5 9 DME 80 H Hygienic Series Diaphragm Pump exploded view...
Страница 39: ...39I DELLMECO I EODD DIAPHRAGM PUMPS DME Plastic Series Flow Characteristics...
Страница 43: ...43I DELLMECO I EODD DIAPHRAGM PUMPS DME Metal Series Flow Characteristics...
Страница 45: ...45I DELLMECO I EODD DIAPHRAGM PUMPS DME Hygienic Series Flow Characteristics...
Страница 65: ...Notes...
Страница 66: ...DELLMECO Swierkowa 2 Glincz 83 330 POLAND tel 48 532 720 222 sales dellmeco com www dellmeco com...