34 I DELLMECO I EODD DIAPHRAGM PUMPS
10.4. Pumping capacity or pressure value is not achieved, pump pumps not uniformly
Cause
Action to take
The suction line is completely or partially blocked.
Clean the suction line.
Permissible suction capacity is exceeded.
Increase fluid level or lower the pump.
The fluid level on the suction side enables air suction or air
emission.
Increase fluid level.
Solid substances are depositing during still stand.
Flush or drain the pump.
Solid substance contents and/or grain size is too high.
Install a coarse filter before the pump.
The balls and/or valve seats are worn out.
Disassemble the pump, replace parts.
The valve ball is jammed due to solid substances in guides.
Insert heavier balls, reduce ball diameters.
Diaphragm damage.
Disassemble the pump, check and replace component.
10.5. Pump works loudly
Cause
Action to take
The suction line is completely or partially blocked.
Clean the suction line.
Permissible suction capacity is exceeded.
Increase fluid level or lower the pump.
Too high revolution.
Decrease revolution down to allowable value.
Bearings damaged in the diaphragm drive.
Bearings need to be replaced
– send pump for repair.
10.6. Pump does not operate anymore
Cause
Action to take
The suction line is completely or partially blocked.
Clean the suction line.
Permissible suction capacity is exceeded.
Increase fluid level or lower the pump.
Solid substances are depositing during still stand.
Flush or drain the pump.
Solid substance contents and/or grain size is too high.
Install a coarse filter before the pump.
The valve ball is jammed due to solid substances in guides.
Insert heavier balls, reduce ball diameters.
Diaphragm damage.
Disassemble the pump, check and replace component.
10.7. Irregular noise
Cause
Action to take
The pump is clogged with sludge with particles of larger
than the permissible diameter.
Disassemble the casing, check and clean.
10.8. Irregular vibration
Cause
Action to take
Connection parts and pump mounting are loose.
Check each connection part and tighten the bolts.
If any of the above mentioned causes do not apply to your problem, contact your dealer
or our office.
Содержание DME 15 R Series
Страница 11: ...11I DELLMECO I EODD DIAPHRAGM PUMPS 5 2 DME 40 50 R Z and DME 80 R Plastic Series Diaphragm Pump exploded view...
Страница 14: ...14 I DELLMECO I EODD DIAPHRAGM PUMPS 5 3 DME 20 25 40 A C S Metal Series Diaphragm Pump exploded view...
Страница 15: ...15I DELLMECO I EODD DIAPHRAGM PUMPS 5 4 DME 50 A C S Metal Series Diaphragm Pump exploded view...
Страница 16: ...16 I DELLMECO I EODD DIAPHRAGM PUMPS 5 5 DME 80 A B Metal Series Diaphragm Pump exploded view...
Страница 17: ...17I DELLMECO I EODD DIAPHRAGM PUMPS 5 6 DME 80 S Metal Series Diaphragm Pump exploded view...
Страница 20: ...20 I DELLMECO I EODD DIAPHRAGM PUMPS 5 7 DME 25 40 50 H Hygienic Series Diaphragm Pump exploded view...
Страница 21: ...21I DELLMECO I EODD DIAPHRAGM PUMPS 5 8 DME 65 H Hygienic Series Diaphragm Pump exploded view...
Страница 22: ...22 I DELLMECO I EODD DIAPHRAGM PUMPS 5 9 DME 80 H Hygienic Series Diaphragm Pump exploded view...
Страница 39: ...39I DELLMECO I EODD DIAPHRAGM PUMPS DME Plastic Series Flow Characteristics...
Страница 43: ...43I DELLMECO I EODD DIAPHRAGM PUMPS DME Metal Series Flow Characteristics...
Страница 45: ...45I DELLMECO I EODD DIAPHRAGM PUMPS DME Hygienic Series Flow Characteristics...
Страница 65: ...Notes...
Страница 66: ...DELLMECO Swierkowa 2 Glincz 83 330 POLAND tel 48 532 720 222 sales dellmeco com www dellmeco com...