27I DELLMECO I EODD DIAPHRAGM PUMPS
6.2. Mounting the DME Pumps
!
CAUTION
!
WARNING
Examine all parts for transport damages at receipt. Immediately inform the shipping company in writing of
the found damages.
Examine individual parts for damages in detail. Immediately inform the manufacturer in writing if any
damages have been found.
Vibration generated by pump operation should be absorbed. Take it into consideration when mounting it.
The running pump may generate noise. Its level will depend upon conditions of use (kind of fluid being
pumped, discharge pressure).
Install a cushioned pressure gauge (range up to 0.6 MPa or 1.0 MPa) on the discharge side to measure a
pressure ratio. A vacuum gauge (range: -0.1 to +0.1 MPa) is also recommended in the suction line.
In the event that a cut-off device is located in the discharge line, or there is a possibility that a discharge
line is added, a safety device must be provided (e.g. a pressure switch with differential pressure control,
contact pressure gauge, etc.).
A suction flow stabilizer is advisable in the event that:
-
suction line is longer than 3 meters
-
suction head is longer than 3 meters
In the event that the medium to be pumped is slightly gas-emitting, a positive head must be created at the
suction side of the pump.
In the event that pumping is carried out to a pressure line or against a pressure control valve, an air valve
must be installed in the discharge line.
DME Series Pumps are not intended to be working in total or partial submersion.
The end of the hose must be equipped with a pit, a protection box, etc. (in case the diaphragm gets
damaged and a leakage of the fluid follows).
Pump exhaust should be directed to a safe place, away from people, animals and food.
Содержание DME 15 R Series
Страница 11: ...11I DELLMECO I EODD DIAPHRAGM PUMPS 5 2 DME 40 50 R Z and DME 80 R Plastic Series Diaphragm Pump exploded view...
Страница 14: ...14 I DELLMECO I EODD DIAPHRAGM PUMPS 5 3 DME 20 25 40 A C S Metal Series Diaphragm Pump exploded view...
Страница 15: ...15I DELLMECO I EODD DIAPHRAGM PUMPS 5 4 DME 50 A C S Metal Series Diaphragm Pump exploded view...
Страница 16: ...16 I DELLMECO I EODD DIAPHRAGM PUMPS 5 5 DME 80 A B Metal Series Diaphragm Pump exploded view...
Страница 17: ...17I DELLMECO I EODD DIAPHRAGM PUMPS 5 6 DME 80 S Metal Series Diaphragm Pump exploded view...
Страница 20: ...20 I DELLMECO I EODD DIAPHRAGM PUMPS 5 7 DME 25 40 50 H Hygienic Series Diaphragm Pump exploded view...
Страница 21: ...21I DELLMECO I EODD DIAPHRAGM PUMPS 5 8 DME 65 H Hygienic Series Diaphragm Pump exploded view...
Страница 22: ...22 I DELLMECO I EODD DIAPHRAGM PUMPS 5 9 DME 80 H Hygienic Series Diaphragm Pump exploded view...
Страница 39: ...39I DELLMECO I EODD DIAPHRAGM PUMPS DME Plastic Series Flow Characteristics...
Страница 43: ...43I DELLMECO I EODD DIAPHRAGM PUMPS DME Metal Series Flow Characteristics...
Страница 45: ...45I DELLMECO I EODD DIAPHRAGM PUMPS DME Hygienic Series Flow Characteristics...
Страница 65: ...Notes...
Страница 66: ...DELLMECO Swierkowa 2 Glincz 83 330 POLAND tel 48 532 720 222 sales dellmeco com www dellmeco com...