900160019
Journal protection in the event of a power failure not enabled.
Description
OneFS failed to enable the subsystem that copies the contents of the local and peer node journals to the M.2 vault card in the
event of power loss.
If the node loses power unexpectedly, OneFS will not be able to copy the journals.
The event message provides you with the chassis and node slot of the affected node.
Administrator action
You can attempt to enable the subsystem by running the following command:
isi_pmp -a
If the subsystem is not enabled, there may be an issue with the M.2 vault card or another component in the node.
If the event persists, gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to
gather cluster logs, see
.
900160020
A hardware error was corrected.
Description
This event can be an indicator of issues with a compute node. The compute node might need to be replaced. The compute node
is not a customer-replaceable part.
The event message provides you with the chassis and node slot of the affected node.
Administrator action
Gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to gather cluster logs,
see
.
900160021
A node's Baseboard Management Controller (BMC) is not responding.
Description
The BMC monitors hardware components such as batteries and power supplies. To make sure that these hardware components
continue to be monitored, the node must be serviced immediately. Troubleshooting is required to determine if a hardware
component must be replaced.
The event message provides you with the chassis and node slot of the affected node.
190