Administrator action
We recommend that you destroy the drive data according to your company's security regulations.
100010032
A used drive from another cluster was inserted as a replacement.
Description
A drive that was installed as a replacement was used previously in a different cluster. The event message provides you with the
current node, bay, location, drive type, and Logical Number (LNUM) of the drive.
Administrator action
Take one of the following actions to resolve the issue:
●
If the drive was inserted in error, replace the drive with a new drive according to the instructions in the
PowerScale Drive
Replacement Guide
for your platform.
●
If you want to use the drive that was inserted, you need to re-format the drive to erase it.
100010033
A used drive from another node in the cluster was inserted as a replacement.
Description
A drive that was installed as a replacement was used previously in the cluster. The event message provides you with the current
node, bay, location, drive type, and Logical Number (LNUM) of the drive.
Administrator action
Take one of the following actions to resolve the issue:
●
If the drive was inserted in error, replace the drive with a new drive according to the instructions in the
PowerScale Drive
Replacement Guide
for your platform.
●
If you want to use the drive that was inserted, you need to re-format the drive to erase it.
100010034
A FlexProtect job is in progress for a drive.
Description
Flexprotect is currently preparing a drive to be added to the filesystem. The event message provides you with the current node,
bay, location, drive type, and Logical Number (LNUM) of the drive.
Administrator action
This message is informational. No action is required.
44
Software events