32
About Your System
E1810
Hard drive ##
fault. Review
& clear SEL.
The specified hard drive
has experienced a fault.
See "Troubleshooting a
Hard Drive" on page 174.
E1812
Hard drive ##
removed. Check
drive.
The specified hard drive
has been removed from
the system.
Information only.
E1920
iDRAC6 Upgrade
Failed
The iDRAC6 Express card
is not installed properly or
the card is bad.
If the problem persists,
see "Getting Help" on
page 193.
E1A14
SAS cable A
failure. Check
connection.
SAS cable A is missing or
bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 193.
E1A15
SAS cable B
failure. Check
connection.
SAS cable B is missing or
bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 193.
E1A1D
Control panel
USB cable not
detected.
Check cable.
USB cable to the control
panel is missing or bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 193.
E2010
Memory not
detected.
Inspect DIMMs.
No memory was detected
in the system.
Install or reseat memory
modules. See "Installing
Memory Modules" on
page 104 or
"Troubleshooting System
Memory" on page 167.
Table 1-1.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 32 Monday, June 15, 2009 11:33 AM
Содержание PowerEdge T710
Страница 1: ...Dell PowerEdge T710 Systems Hardware Owner s Manual ...
Страница 78: ...78 Using the System Setup Program and UEFI Boot Manager ...
Страница 80: ...80 Installing System Components Figure 3 1 Inside the System 1 4 7 15 2 16 8 5 14 13 6 9 11 3 12 17 10 ...
Страница 194: ...194 Getting Help ...
Страница 204: ...204 Glossary ...
Страница 210: ...Index 210 ...
Страница 211: ...Index 211 ...
Страница 212: ...212 Index ...
Страница 213: ...Index 213 ...
Страница 214: ...214 Index ...