E2011
Memory
configuration
failure. Check
DIMMs.
Memory detected, but is
not configurable. Error
detected during memory
configuration.
See "Troubleshooting
System Memory" on
page 167.
E2012
Memory
configured but
unusable.
Check DIMMs.
Memory configured, but is
unusable.
See "Troubleshooting
System Memory" on
page 167.
E2013
BIOS unable to
shadow memory.
Check DIMMs.
The system BIOS failed to
copy its flash image into
memory.
See "Troubleshooting
System Memory" on
page 167.
E2014
CMOS RAM
failure. Power
cycle AC.
CMOS failure. CMOS
RAM not functioning
properly.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 193.
E2015
DMA Controller
failure. Power
cycle AC.
DMA controller failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 193.
E2016
Interrupt
Controller
failure. Power
cycle AC.
Interrupt controller
failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 193.
E2017
Timer refresh
failure. Power
cycle AC.
Timer refresh failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 193.
Table 1-1.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 33 Monday, June 15, 2009 11:33 AM
Содержание PowerEdge T710
Страница 1: ...Dell PowerEdge T710 Systems Hardware Owner s Manual ...
Страница 78: ...78 Using the System Setup Program and UEFI Boot Manager ...
Страница 80: ...80 Installing System Components Figure 3 1 Inside the System 1 4 7 15 2 16 8 5 14 13 6 9 11 3 12 17 10 ...
Страница 194: ...194 Getting Help ...
Страница 204: ...204 Glossary ...
Страница 210: ...Index 210 ...
Страница 211: ...Index 211 ...
Страница 212: ...212 Index ...
Страница 213: ...Index 213 ...
Страница 214: ...214 Index ...