About Your System
19
Data error
The diskette drive or hard
drive cannot read the data.
For the operating system,
run the appropriate utility
to check the file structure
of the diskette drive or hard
drive.
See your operating system
documentation for
information on running
these utilities.
Decreasing
available memory
One or more memory
modules might be
improperly seated or faulty.
Reinstall the memory
modules and, if necessary,
replace them. See
"Memory" on page 76.
See "Troubleshooting
System Memory" on
page 118.
Diskette read
failure
Faulty or improperly
inserted diskette.
Replace the diskette.
Diskette subsystem
reset failed
Faulty diskette drive or
optical drive controller.
Ensure that the diskette
drive and optical drive
cables are properly
connected. See
"Troubleshooting a USB
Device" on page 110 and
"Troubleshooting an
Optical Drive" on page 122.
If the problem persists, see
"Getting Help" on
page 141.
Drive not ready
Diskette missing or
improperly inserted in
diskette drive.
Reinsert or replace the
diskette.
Table 1-6.
System Messages
(continued)
Message
Causes
Corrective Actions