About Your System
33
E1A12
PCI Riser not
detected.
Check Riser.
One or both of the PCIe
risers are missing. This
prevents the system from
powering on.
Reinstall the missing riser
card(s). See "Installing
Expansion-Card Riser 1"
on page 121 and
"Installing Expansion-
Card Riser 2" on page 122.
E1813
Internal Dual
SD Module
Card #
failed. Check
SD card
The internal dual SD
module card failed.
Reseat the internal dual
SD module card.
If the problem persists,
see "Getting Help" on
page 195.
E1814
Internal SD
Module Card #
write-
protected.
Check SD card
The internal dual SD
module card is write-
protected and cannot be
used.
Change the write-protect
switch setting on SD card.
E1815
Internal Dual
SD Module
redundancy
lost. Check
SD cards
The internal dual SD
module bootable media is
no longer redundant.
Reseat the internal dual
SD module card.
If the problem persists,
see "Getting Help" on
page 195.
E1A14
SAS cable A
failure.
Check
connection.
SAS cable A is missing or
bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 195.
E1A15
SAS cable B
failure.
Check
connection.
SAS cable B is missing or
bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 195
Code
Text
Causes
Corrective Actions
book.book Page 33 Thursday, February 18, 2010 2:06 PM
Содержание PowerEdge R810
Страница 1: ...Dell PowerEdge R810 Hardware Owner s Manual Regulatory Model E05S Regulatory Type E05S001 ...
Страница 80: ...80 Using the System Setup Program and UEFI Boot Manager ...
Страница 135: ...Installing System Components 135 Figure 3 23 Installing and Removing the Heat Sink 1 heat sink 2 release levers 2 1 2 ...
Страница 160: ...160 Installing System Components ...
Страница 194: ...194 Jumpers and Connectors ...
Страница 196: ...196 Getting Help ...
Страница 202: ...Index 202 ...