28
About Your System
E1422
CPU # machine
check error.
Power cycle
AC.
The system BIOS reported a
machine check error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 195.
E1610
Power Supply
# (### W)
missing.
Check power
supply.
Specified power supply
removed or is missing from
the system.
See "Troubleshooting
Power Supplies" on
page 167.
E1614
Power Supply
# (### W)
error. Check
power supply.
Specified power supply
failed.
See "Troubleshooting
Power Supplies" on
page 167.
E1618
Predictive
failure on
Power Supply
# (### W).
Check PSU.
A power supply fan failure,
an over-temperature
condition, or power supply
communication error caused
the predictive warning of an
impending power supply
failure.
See "Troubleshooting
Power Supplies" on
page 167.
E161C
Power Supply
# (### W)
lost AC
power. Check
PSU cables.
Specified power supply
attached to the system, but
lost its AC input.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies" on page 167.
E1620
Power Supply
# (### W) AC
power error.
Check PSU
cables.
Specified power supply's AC
input is outside the
allowable range.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies" on page 167.
Code
Text
Causes
Corrective Actions
book.book Page 28 Thursday, February 18, 2010 2:06 PM
Содержание PowerEdge R810
Страница 1: ...Dell PowerEdge R810 Hardware Owner s Manual Regulatory Model E05S Regulatory Type E05S001 ...
Страница 80: ...80 Using the System Setup Program and UEFI Boot Manager ...
Страница 135: ...Installing System Components 135 Figure 3 23 Installing and Removing the Heat Sink 1 heat sink 2 release levers 2 1 2 ...
Страница 160: ...160 Installing System Components ...
Страница 194: ...194 Jumpers and Connectors ...
Страница 196: ...196 Getting Help ...
Страница 202: ...Index 202 ...