Error Code
Message Information
FAN0001
Message
Fan <
number
> RPM is less than the lower critical threshold.
Details
Fan operating speed is out of range.
Action
Remove and reinstall the fan. If the issue persists, see
Getting
Help
.
HWC1001
Message
The <
name
> is absent.
Details
The absent device may be necessary for proper operation.
System functionality may be degraded.
Action
Reinstall or reconnect the hardware.
HWC2003
Message
The storage <
name
> cable is not connected, or is improperly
connected.
Details
The cable may be necessary for proper operation. System
functionality may be degraded.
Action
Check if the cable is present, then reinstall or reconnect.
HWC2005
Message
The system board <
name
> cable is not connected, or is
improperly connected.
Details
The cable may be necessary for proper operation. System
functionality may be degraded.
Action
Check if the cable is present, then reinstall or reconnect.
MEM0000
Message
Persistent correctable memory errors detected on a memory
device at location(s) <
location
>.
Details
This is an early indicator of a possible future uncorrectable
error.
Action
Re-seat the memory modules. If the issue persists, see
Getting Help
.
MEM0001
Message
Multi-bit memory errors detected on a memory device at
location(s) <
location
>.
Details
The memory module has encountered an uncorrectable
error. System performance may be degraded. The operating
system and/or applications may fail as a result.
Action
Re-seat the memory modules. If the issue persists, see
Getting Help
.