Error Code
Message Information
Action
Review system logs for power or thermal exceptions.
CPU0023
Message
CPU <
number
> is absent.
Action
Verify processor installation. If present, re-seat the
processor.
CPU0204
Message
CPU <
number
> <
name
> voltage is outside of range.
Details
Voltages outside the allowable range may damage electrical
components or may cause the system to shutdown.
Action
1.
Turn off the system and remove input power for one
minute.
2.
Ensure the processor is seated correctly.
3.
Reapply input power and turn on the system.
4.
If the issue persists, see
Getting Help
.
CPU0700
Message
CPU <
number
> initialization error detected.
Details
System BIOS was unable to initialize the processor.
Action
1.
Turn off the system and remove input power for one
minute.
2.
Ensure the processor is seated correctly.
3.
Reapply input power and turn on the system.
4.
If the issue persists, see
Getting Help
.
CPU0701
Message
CPU <
number
> protocol error detected.
Details
System event log and operating system logs may indicate
that the exception is external to the processor.
Action
1.
Check system and operating system logs for exceptions.
If no exceptions are found, continue.
2.
Turn off the system and remove input power for one
minute.
3.
Ensure the processor is seated correctly.
4.
Reapply input power and turn on the system.
5.
If the issue persists, see
Getting Help
.
CPU0702
Message
CPU bus parity error detected.