CMC Indicators
Figure 22. CMC Indicators
1.
status/identification indicator (CMC 1)
2.
power indicator (CMC 1)
3.
power indicator (CMC 2)
4.
status/identification indicator (CMC 2)
The CMC indicators on the back panel of the enclosure provide the following information:
Indicator
Description
Power indicator
Green
The CMC is receiving power.
Off
The CMC is not receiving power.
Status indicator
Blue
The CMC is active and operating normally.
Amber
The CMC is in fault condition.
CMC Features
The CMC provides the following multiple systems management functions:
•
Enclosure-level real-time automatic power and thermal management:
– Monitors system power requirements and supports the optional Dynamic Power Supply Engagement (DPSE)
mode. The DPSE mode improves power efficiency by allowing the CMC to dynamically place power supplies in
standby mode, depending on the load and redundancy requirements.
– Reports real-time power consumption, which includes logging high and low points with a time stamp.
– Supports setting an optional enclosure Maximum Power Limit, which either alerts or takes actions, such as
throttling server modules and/or preventing the power up of new server modules to keep the enclosure under
the defined maximum power limit.
– Monitors and automatically controls cooling fans based on actual ambient and internal temperature
measurements.
30
Содержание PowerEdge M520
Страница 1: ...Dell PowerEdge VRTX Enclosure Owner s Manual Regulatory Model E22S Regulatory Type E22S001 ...
Страница 8: ...8 ...
Страница 34: ...34 ...
Страница 66: ...Figure 45 Securing the Power Cable Without Wheel Assembly 1 power cable 2 strap 66 ...
Страница 148: ...148 ...
Страница 151: ...Figure 94 System Board Connectors Back 1 midplane planar connectors 3 151 ...
Страница 152: ...152 ...
Страница 158: ...158 ...