16. Slide the control panel board out of the control panel.
Figure 76. Removing and Installing the Control Panel Board
1.
metal standoffs (2)
2.
control panel board
3.
screws (2)
4.
control panel
Installing The Control Panel Board
CAUTION: This procedure is intended to be performed by Dell Support only.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1.
Align the slots on the control panel board with the metal standoffs on the control panel and slide the control panel
board into the control panel.
When firmly seated, the KVM connectors on the control panel board align with the slots on the control panel.
2.
Attach the two screws to secure the control panel board to the control panel.
3.
Reconnect the power cable to the control panel board.
4.
Reconnect the LCD module cable to the control panel board.
5.
Reinstall the LCD cable holder.
6.
Reinstall the control panel.
7.
Reconnect the control panel cable to its connector on the system board.
8.
Reinstall the cooling-fan assembly.
9.
Reinstall the cooling shroud.
116
Содержание PowerEdge M520
Страница 1: ...Dell PowerEdge VRTX Enclosure Owner s Manual Regulatory Model E22S Regulatory Type E22S001 ...
Страница 8: ...8 ...
Страница 34: ...34 ...
Страница 66: ...Figure 45 Securing the Power Cable Without Wheel Assembly 1 power cable 2 strap 66 ...
Страница 148: ...148 ...
Страница 151: ...Figure 94 System Board Connectors Back 1 midplane planar connectors 3 151 ...
Страница 152: ...152 ...
Страница 158: ...158 ...