Troubleshooting Your System
163
If the hard drive functions properly in the original bay, the drive carrier
could have intermittent problems. Replace the hard-drive carrier.
See
"Getting Help
" on page 181
.
If the hard drive functioned properly in another bay but does not function
in the original bay, the SAS backplane has a defective connector.
See
"Getting Help
" on page 181
.
8
Check the cable connections inside the system:
a
Turn off the system, including any attached peripherals, and
disconnect the system from the electrical outlet.
b
Open the system. See "Opening and Closing the System" on page 67.
c
Verify that the cable connections between the SAS backplane and the
controller card are correct. See "Installing a SAS Controller Card" on
page 114.
d
Verify that the data cables are securely seated in their connectors.
e
Verify that the power connector on the SAS backplane is securely
seated in its connector.
f
Close the system. See "Opening and Closing the System" on page 67.
g
Reconnect the system to the electrical outlet, and turn on the system
and attached peripherals.
If the problem persists,
see "Getting Help
" on page 181
.
Troubleshooting a SAS Controller or SAS RAID
Controller
NOTE:
When troubleshooting a SAS or SAS RAID controller, also see the
documentation for your operating system and the controller.
Problem
•
Error message indicates a problem with the SAS or SAS RAID controller.
•
SAS or SAS RAID controller performs incorrectly or not at all.
Содержание PowerEdge HX574
Страница 1: ...Dell PowerEdge R905 Hardware Owner s Manual ...
Страница 10: ...10 Contents 7 Getting Help 181 Contacting Dell 181 Glossary 183 Index 195 ...
Страница 44: ...44 About Your System ...
Страница 62: ...62 Using the System Setup Program ...
Страница 144: ...144 Installing System Components ...
Страница 182: ...182 Getting Help ...
Страница 194: ...194 Glossary ...