100
Installing System Components
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.
CAUTION:
The memory modules are hot to the touch for some time after the
system has been powered down. Allow time for the memory modules to cool
before handling them. Handle the memory modules by the card edges and avoid
touching the components on the memory module.
1
Turn off the system, including any attached peripherals, and disconnect
the system from the electrical outlet.
2
Open the system. See "Opening the System" on page 67.
3
Remove the PEM. See "Removing the PEM or PEM Shell" on page 75.
4
Remove the cooling shroud assembly:
–
If you are removing memory modules on the system board, see
"Removing the Cooling Shroud Assembly" on page 71.
–
If you are removing memory modules on the PEM, see Figure 3-9.
5
Locate the memory module sockets. See Figure 6-1.
6
Press down and out on the ejectors on each end of the socket until the
memory module pops out of the socket. See Figure 3-18.
Handle each memory module only on either card edge, ensuring not to
touch the middle of the memory module.
7
Replace the cooling shroud assembly:
–
If you are removing memory modules on the system board, see
"Replacing the Cooling Shroud Assembly" on page 72.
–
If you are removing memory modules on the PEM, see Figure 3-9.
8
Replace the PEM. See "Replacing the PEM or PEM Shell" on page 78.
9
Close the system. See "Closing the System" on page 68.
Processors
Your system supports either two or four processors. You can upgrade
processors to take advantage of future options in speed and functionality.
Each processor and its associated internal cache memory are contained in a
land grid array (LGA) package that is installed in a socket on the system board
or processor expansion module.
Содержание PowerEdge HX574
Страница 1: ...Dell PowerEdge R905 Hardware Owner s Manual ...
Страница 10: ...10 Contents 7 Getting Help 181 Contacting Dell 181 Glossary 183 Index 195 ...
Страница 44: ...44 About Your System ...
Страница 62: ...62 Using the System Setup Program ...
Страница 144: ...144 Installing System Components ...
Страница 182: ...182 Getting Help ...
Страница 194: ...194 Glossary ...