38
About Your System
No boot sector on
hard drive
Incorrect configuration
settings in System Setup
program, or no operating
system on hard drive.
Check the hard-drive
configuration settings in
the System Setup program.
See "Using the System
Setup Program" on page 45.
If necessary, install the
operating system on your
hard drive. See your
operating system
documentation.
No timer tick
interrupt
Faulty system board.
See "Getting Help" on
page 181.
Optical drive not
found
Cable is not properly
seated, or drive is missing.
See "Troubleshooting an
Optical Drive" on page 160.
PCIe Degraded Link
Width Error:
Embedded
Bus#
nn
/Dev#
nn
/Func
n
Expected Link
Width is
n
Actual Link Width
is
n
Faulty or improperly
installed PCIe card in the
specified slot.
Reseat the PCIe card in the
specified slot number. See
"Installing an Expansion
Card" on page 80. If the
problem persists, see
"Getting Help" on
page 181.
PCIe Fatal Error
caused a system
reset: Slot
n
or
Embedded
Bus#
nn
/Dev#
nn
/Func
n
Please check the
system event log
for details.
Faulty or improperly
installed PCIe card in the
specified slot.
Reseat the PCIe card in the
specified slot number. See
"Installing an Expansion
Card" on page 80. If the
problem persists, see
"Getting Help" on
page 181.
Table 1-8.
System Messages
(continued)
Message
Causes
Corrective Actions
Содержание PowerEdge HX574
Страница 1: ...Dell PowerEdge R905 Hardware Owner s Manual ...
Страница 10: ...10 Contents 7 Getting Help 181 Contacting Dell 181 Glossary 183 Index 195 ...
Страница 44: ...44 About Your System ...
Страница 62: ...62 Using the System Setup Program ...
Страница 144: ...144 Installing System Components ...
Страница 182: ...182 Getting Help ...
Страница 194: ...194 Glossary ...