Rebuilding A Failed Physical Disk
Issue:
Rebuilding a physical disk that is in a failed state.
Corrective
Action:
If you have configured hot spares, the PERC card automatically tries to use one of
the hot spares to rebuild a physical disk that is in a failed state. Manual rebuild is
necessary if no hot spares with enough capacity to rebuild the failed physical disks
are available. You must insert a physical disk with enough storage in the subsystem
before rebuilding the physical disk.
NOTE: You can use the
BIOS Configuration Utility
(<Ctrl> <R>) or Dell OpenManage storage
management application to perform a manual rebuild of an individual physical disk. For information
on rebuilding a single physical disk, see
Performing A Manual Rebuild Of An Individual Physical Disk
.
Virtual Disk Fails During Rebuild Using A Global Hot Spare
Issue:
A virtual disk fails during rebuild while using a global hot spare.
Description:
The global hot spare reverts to
Hotspare
state and the virtual disk is in
Failed
state.
Virtual Disk Fails During Rebuild Using A Dedicated Hot Spare
Issue:
A virtual disk fails during rebuild while using a dedicated hot spare.
Description:
The dedicated hot spare reverts to
Ready
state and the virtual disk goes to
Failed
state.
Physical Disk Fails During Reconstruction On Redundant Virtual Disk
Issue:
A physical disk fails during a reconstruction process on a redundant virtual disk that
has a hot spare.
Corrective
Action:
The dedicated hot spare reverts to
Ready
state and the virtual disk goes to
Failed
state.
Virtual Disk Fails Rebuild Using A Dedicated Hot Spare
Issue:
A virtual disk fails during rebuild while using a dedicated hot spare.
Description:
The dedicated hot spare is in
Ready
state and the virtual disk is in
Failed
state.
Physical Disk Takes A Long Time To Rebuild
Issue:
A physical disk is taking longer than expected to rebuild.
Description:
A physical disk takes longer to rebuild when under high stress. For example, there is
one rebuild I/O operation for every five host I/O operations. You cannot add a
second virtual disk to a disk group while the virtual disk in that disk group is
undergoing a rebuild. The firmware does not allow you to create a virtual disk using
the free space available in a disk group if a physical disk in a virtual disk group is
undergoing a rebuild operation.
80
Содержание PowerEdge H730P
Страница 9: ...Contacting Dell 101 Documentation Feedback 101 Locating Your System Service Tag 101 ...
Страница 10: ...10 ...
Страница 14: ...14 ...
Страница 32: ...11 backplane jumper cable connector on the backplane 32 ...
Страница 38: ...38 ...
Страница 70: ...70 ...
Страница 84: ...Figure 5 Disk Carrier LED Indicators 1 activity LED 2 status LED 84 ...
Страница 100: ...100 ...