Displaying Foreign Configuration
Syntax
perccli /c0/fall show
Description
Displays the entire foreign configuration for specified controller.
Result
Controller = 0
Status = Success
Description = Operation on foreign configuration Succeeded
FOREIGN CONFIGURATION :
=====================
---------------------------------------
DG EID:Slot Type State Size NoVDs
---------------------------------------
0 - RAID0 Frgn 372.0 GB 1
---------------------------------------
NoVDs - Number of VDs in disk group|DG - Diskgroup
Total foreign drive groups = 1
Importing Foreign Configuration
Syntax
perccli /c0/fall import
Description
Imports the foreign configurations for the specified controller.
Result
Controller = 0
Status = Success
Description = Successfully imported foreign configuration
Displaying BBU Information
Syntax
perccli /c0/bbu show all
Description
Displays information related to Battery Backup Unit (BBU) of a controller.