Troubleshooting
75
PERC 5 Post Error Messages
In PERC 5 controllers, the BIOS (read-only memory, ROM) provides INT 13h functionality (disk I/O) for
the virtual disks connected to the controller, so that you can boot from or access the physical disks without
the need of a driver. Table 6-5 describes the error messages and warnings that display for the BIOS.
Table 6-5.
BIOS Errors and Warnings
Message
Meaning
BIOS Disabled. No Logical Drives
Handled by BIOS
This warning displays after you disable the
ROM
option in the
configuration utility. When the
ROM
option is disabled, the BIOS
cannot hook Int13h and cannot provide the ability to boot from
the virtual disk. (Int13h is an interrupt signal that supports
numerous commands that are sent to the BIOS, then passed to
the physical disk. The commands include actions you can perform
with a physical disk, such as reading, writing, and formatting.)
Press
<Ctrl><R>
to Enable BIOS
When the BIOS is disabled, you are given the option to enable it
by entering the configuration utility. You can change the setting to
Enabled
in the configuration utility.
Adapter at Baseport xxxx is not
responding
where xxxx is the baseport of the
controller
If the controller does not respond for any reason but is detected by
the BIOS, it displays this warning and continues.
Shut down the system and try to reseat the controller. If this
message still occurs, contact Dell Technical Support.
x Virtual Disk(s) Failed
where x is the number of virtual
disks failed
When the BIOS detects virtual disks in the failed state, it displays
this warning. You should check to determine why the virtual disks
failed and correct the problem. No action is taken by the BIOS.
x Virtual Disk(s) Degraded
where x is the number of virtual
disks degraded
When the BIOS detects virtual disks in a degraded state, it
displays this warning. You should try to make the virtual disks
optimal. No action is taken by the BIOS.
Memory/Battery problems were
detected. The adapter has
recovered, but cached data was
lost. Press any key to continue.
This message occurs under the following conditions:
• The adapter detects that the cache in the controller cache has not
yet been written to the disk subsystem
• The controller detects an error-correcting code (ECC) error while
performing its cache checking routine during initialization
• The controller then discards the cache rather than sending it to
the disk subsystem because the data integrity cannot be
guaranteed
To resolve this problem, allow the battery to charge fully. If the
problem persists, the battery or adapter DIMM might be faulty. In
that case, contact Dell Technical Support.
Firmware is in Fault State
Contact Dell Technical Support.
Dell_PERC5_UG.book Page 75 Tuesday, February 13, 2007 6:02 PM
Содержание PowerEdge 5/E
Страница 2: ...Dell_PERC5_UG book Page 2 Tuesday February 13 2007 6 02 PM ...
Страница 10: ...8 Contents Dell_PERC5_UG book Page 8 Tuesday February 13 2007 6 02 PM ...
Страница 26: ...24 PERC 5 Features Dell_PERC5_UG book Page 24 Tuesday February 13 2007 6 02 PM ...
Страница 50: ...48 Driver Installation Dell_PERC5_UG book Page 48 Tuesday February 13 2007 6 02 PM ...
Страница 87: ...Appendix Regulatory Notices 85 Dell_PERC5_UG book Page 85 Tuesday February 13 2007 6 02 PM ...
Страница 88: ...86 Appendix Regulatory Notices Dell_PERC5_UG book Page 86 Tuesday February 13 2007 6 02 PM ...
Страница 89: ...Appendix Regulatory Notices 87 Dell_PERC5_UG book Page 87 Tuesday February 13 2007 6 02 PM ...
Страница 90: ...88 Appendix Regulatory Notices Dell_PERC5_UG book Page 88 Tuesday February 13 2007 6 02 PM ...
Страница 91: ...Appendix Regulatory Notices 89 Dell_PERC5_UG book Page 89 Tuesday February 13 2007 6 02 PM ...
Страница 92: ...90 Appendix Regulatory Notices Dell_PERC5_UG book Page 90 Tuesday February 13 2007 6 02 PM ...
Страница 93: ...Appendix Regulatory Notices 91 Dell_PERC5_UG book Page 91 Tuesday February 13 2007 6 02 PM ...
Страница 95: ...Appendix Regulatory Notices 93 VCCI Japan Only Dell_PERC5_UG book Page 93 Tuesday February 13 2007 6 02 PM ...
Страница 98: ...96 Appendix Regulatory Notices Dell_PERC5_UG book Page 96 Tuesday February 13 2007 6 02 PM ...
Страница 99: ...Appendix Regulatory Notices 97 Dell_PERC5_UG book Page 97 Tuesday February 13 2007 6 02 PM ...
Страница 100: ...98 Appendix Regulatory Notices Dell_PERC5_UG book Page 98 Tuesday February 13 2007 6 02 PM ...