RAID Configuration and Management
61
e
Press <Tab> to move the cursor to the
Read Policy
to change it if desired.
f
Press <Enter> to display the options,
Read Ahd
,
No Read
,
or
Adaptive
, then press the down
arrow key to highlight an option and press <Enter>.
g
Press <Tab> to move the cursor to the
Write Policy
to change it if desired.
h
Press <Enter> to display the options,
Write-Through
or
Write-Back
, then press the down arrow
key to highlight an option and press <Enter>.
i
Press <Tab> to move the cursor to
OK
.
j
Press <Tab> to move the cursor to
Force WB with no battery
and press <Enter>.
k
Press <Tab> to move the cursor to
Initialize
and press <Enter>.
NOTE:
The initialization performed at this stage is fast initialization.
l
Press <Tab> to move the cursor to
Configure Hot Spare
and press <Enter>.
NOTE:
The hot spare created at this stage is a dedicated hot spare.
m
If you have chosen to create hot spares in the earlier steps a pop-up window appears where drives
with appropriate sizes are displayed. Press the spacebar to select the drive size.
n
After you select the drive size, click
OK
to finalize the selection or click
Cancel
to forfeit the
selection.
o
Select
OK
to accept the settings and press <Enter> to exit this window or select
Cancel
and
press <Enter> to exit if you do not want to change any virtual disk parameters.
Initializing Virtual Disks
Perform the following steps to initialize virtual disks.
1
On the
VD Mgmt
screen, select
Virtual Disk #
and press <F2> to display the menu of available
actions.
2
Select
Initialization
and press the right arrow key to display the
Initialization
submenu options.
3
Select
Start Init.
to begin a regular initialization or select
Fast Init.
to begin a fast initialization.
Fast initialization writes zeroes to the first sector of the virtual disk so that initialization occurs in
2–3 seconds. A progress bar displays next to the selected virtual disk as it initializes.
4
When initialization is complete, press <Esc> to return to the main menu screen.
5
Repeat the procedures in this section to configure another virtual disk.
The PERC 5 controllers support up to 64 virtual disks per controller. The currently configured virtual
disks display on the screen.
NOTE:
Performing a full initialization eliminates the need for the virtual disk to undergo a background initialization.
The full initialization is faster than the background initialization. Full initialization can be performed to speed up
performance access to the virtual disk after initial creation. The full initialization must be completed before
accessing the virtual disk.
Dell_PERC5_UG.book Page 61 Tuesday, February 13, 2007 6:02 PM
Содержание PowerEdge 5/E
Страница 2: ...Dell_PERC5_UG book Page 2 Tuesday February 13 2007 6 02 PM ...
Страница 10: ...8 Contents Dell_PERC5_UG book Page 8 Tuesday February 13 2007 6 02 PM ...
Страница 26: ...24 PERC 5 Features Dell_PERC5_UG book Page 24 Tuesday February 13 2007 6 02 PM ...
Страница 50: ...48 Driver Installation Dell_PERC5_UG book Page 48 Tuesday February 13 2007 6 02 PM ...
Страница 87: ...Appendix Regulatory Notices 85 Dell_PERC5_UG book Page 85 Tuesday February 13 2007 6 02 PM ...
Страница 88: ...86 Appendix Regulatory Notices Dell_PERC5_UG book Page 86 Tuesday February 13 2007 6 02 PM ...
Страница 89: ...Appendix Regulatory Notices 87 Dell_PERC5_UG book Page 87 Tuesday February 13 2007 6 02 PM ...
Страница 90: ...88 Appendix Regulatory Notices Dell_PERC5_UG book Page 88 Tuesday February 13 2007 6 02 PM ...
Страница 91: ...Appendix Regulatory Notices 89 Dell_PERC5_UG book Page 89 Tuesday February 13 2007 6 02 PM ...
Страница 92: ...90 Appendix Regulatory Notices Dell_PERC5_UG book Page 90 Tuesday February 13 2007 6 02 PM ...
Страница 93: ...Appendix Regulatory Notices 91 Dell_PERC5_UG book Page 91 Tuesday February 13 2007 6 02 PM ...
Страница 95: ...Appendix Regulatory Notices 93 VCCI Japan Only Dell_PERC5_UG book Page 93 Tuesday February 13 2007 6 02 PM ...
Страница 98: ...96 Appendix Regulatory Notices Dell_PERC5_UG book Page 96 Tuesday February 13 2007 6 02 PM ...
Страница 99: ...Appendix Regulatory Notices 97 Dell_PERC5_UG book Page 97 Tuesday February 13 2007 6 02 PM ...
Страница 100: ...98 Appendix Regulatory Notices Dell_PERC5_UG book Page 98 Tuesday February 13 2007 6 02 PM ...