background image

53-1002267-01
18 March 2011

PowerConnect B-FCX 
Switch

Hardware Installation Guide

Содержание PowerConnect B-FCX

Страница 1: ...53 1002267 01 18 March 2011 PowerConnect B FCX Switch Hardware Installation Guide ...

Страница 2: ...nect are trademarks of Dell Inc Microsoft Windows and Windows Server are either trademarks or registered trademarks of Microsoft Corporation in the United States and or other countries Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products Dell Inc disclaims any proprietary interest in trademarks and trade names ...

Страница 3: ...Installing the PowerConnect B FCX Switch Unpacking the device 15 Package contents 15 General requirements 15 Installation tasks 16 Installation precautions 16 General precautions 17 Lifting precautions 17 Power precautions 17 Preparing the installation site 18 Cabling infrastructure 18 Installation location 18 Installing the device 19 Desktop installation 19 Rack mount installation 20 Connecting d...

Страница 4: ...6 Connecting network devices 39 Connectors 39 Cable specifications 39 Connecting to Ethernet or fast Ethernet hubs 39 Connecting to workstations servers or routers 40 Connecting a network device to a fiber port 40 Testing connectivity 43 Pinging an IP address 43 Observing LEDs 43 Tracing a route 45 Troubleshooting network connections 45 Using Virtual Cable Testing to diagnose a cable 46 Digital op...

Страница 5: ...ons 62 Power cords 63 AC power supply specifications 63 Chapter 6 Troubleshooting Diagnosing switch indicators 65 Power and cooling problems 65 Installation 65 In band access 66 Appendix A Regulatory Statements USA FCC CFR 47 Part 15 Warning 67 Industry Canada statement 67 Europe and Australia CISPR 22 Class A Warning 67 Japan VCCI 67 Japan power cord 68 Korea 68 Russia 68 Regulatory compliance 69...

Страница 6: ...vi PowerConnect B FCX Switch Hardware Installation Guide 53 1002267 01 ...

Страница 7: ...e following hardware platform is supported in this release PowerConnect B FCX624s PowerConnect B FCX648s PowerConnect B FCX624 PowerConnect B FCX648 Document conventions This section describes text formatting conventions and important notice formats used in this document Text formatting The following narrative text formatting conventions are used in this guide bold text Identifies command names Id...

Страница 8: ... alerts you to situations that can be potentially hazardous to you or cause damage to hardware firmware software or data DANGER A Danger statement indicates conditions or situations that can be potentially lethal or extremely hazardous to you Safety labels are also attached directly to products to warn of these conditions or situations Related publications The following Dell documents supplement t...

Страница 9: ...es call 800 WWW DELL 800 999 3355 NOTE If you do not have an active Internet connection you can find contact information on your purchase invoice packing slip bill or Dell product catalog Dell provides several online and telephone based support and service options Availability varies by country and product and some services may not be available in your area To contact Dell for sales technical supp...

Страница 10: ...x PowerConnect B FCX Switch Hardware Installation Guide 53 1002267 01 ...

Страница 11: ...e device has two management interfaces on the front panel a DB9 serial port Console and an RJ45 port Out of band Management Interface The front panel has a slot for an optional four port 1GbE SFP module works as Combo port or four port 10 Gbps SFP module On the rear panel a removable fan tray provides a cooling airflow from the front to the back FtB of the device Two rear panel power supply recept...

Страница 12: ... 3 protocols RIP OSPF PIM PowerConnect B FCX models can be ordered from the factory as ADV Advanded Layer 3 models which adds support for the Layer 3 BGP routing protocol The following sections describe the physical characteristics of the PowerConnect B FCX models For more details about physical dimensions power supply specifications and pinouts refer to Hardware Specifications on page 57 The foll...

Страница 13: ...r an orange arrow with an I as shown in Table 1 Control features Each device front panel includes the following control features Serial management interface the DB9 port labeled Console 25 27 29 31 33 35 37 39 41 43 45 47 26 28 30 32 34 36 38 40 42 44 46 48 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 Reset 1 PS 2 Diag Console Mgmt TABLE 1 Power supply and fan tray labels for Pow...

Страница 14: ...s 100 1000 ports with mini GBIC slots for MSA compliant SFP transceivers Optional 4 port 1Gbps Ethernet SFP module Optional 4 port 10Gbps Ethernet SFP module PowerConnect B FCX 10 100 1000 BASE T ports All PowerConnect B FCX devices except for the fiber models contain 24 or 48 RJ45 ports that operate at 10 Mbps or 100 Mbps half or full duplex or at 1000 Mbps full duplex Because all ports support a...

Страница 15: ...ts on rear panel or two Gbps XFP ports optional module on front panel Two Gbps XFP ports optional module on front panel PowerConnect B FCX624 devices with optional four port 1 Gbps SFP module 20 10 100 1000 Mbps RJ45 ports plus 4 port 1 Gbps SFP module optional combined with the first four 10 100 1000 Mbps RJ45 copper ports acting as a Combo port N A Optional four port 1 Gbps SFP module PowerConne...

Страница 16: ...ould only be connected to an E1MG BXU at the far end 1000Base BX U M GBXU 1000Base BX U SFP optic SMF transmits at 1310nm and receives at 1490nm LC connector single strand SMF fiber This optic should only be connected to an E1MG BXD at the far end 1000Base LHA M LHA 1000Base LHA SFP optic SMF LC connector Optical Monitoring Capable 1000Base LX M LX 1000Base LX SFP optic SMF LC connector Optical Mo...

Страница 17: ...Gbps SFP module and connecting devices using standard duplex LC cables These devices cannot be combined in a stack with non PowerConnect B FCX devices For detailed information about how to configure PowerConnect B FCX devices in an IronStack topology see the PowerConnect B FCX Series Configuration Guide NOTE The 1 Gbps SFP and 10 Gbps SFP modules are not hot swappable FIGURE 8 Four port 1 Gbps SFP...

Страница 18: ...fications for CX4 stacking ports The following cable specifications apply to the CX4 stacking ports Support for 802 3ak or 10 Gbps Ethernet CX4 standard and 16 Gbps inter unit stacking up to 8 units in a stack Support for cables up to 3 meters in length Requires latch style receptacle or SFF 8470 plug NOTE PowerConnect B FCX624 E PowerConnect B FCX624 I PowerConnect B FCX648 E and PowerConnect B F...

Страница 19: ...shing Amber The port has established a valid link at 10 or 100 Mbps Flashing indicates the port is transmitting and receiving user packets Off A link is not established with a remote port SFP 1F 4F Link or Activity On Flashing Green The SFP port has established a valid link Flashing indicates the port is transmitting and receiving user packets Off A link is not established with a remote port SFP 1...

Страница 20: ...st has detected a fault Blower thermal or any interface fault A or S Active or Standby Green The device is the Active controller If this LED is flashing green the system is initializing Amber Indicates the device is the Standby controller Off Device is operating as a stack member or is in standalone mode Up Link or Down Link Stacking uplink or downlink port status Green Uplink is operating normall...

Страница 21: ...ing Four Green PSU LEDs AC OK Green Green Running Yes DC OK Green Green Single Red DC OK LED AC OK Green Green Running No DC OK Green Red Both DC OK LEDs Red AC OK Green Green Failure No DC OK Red Red One PSU with both AC OK DC OK LEDs Off AC OK Green Off Running No DC OK Green Off DC OK LEDs Red and Off AC OK Green Off Failure No DC OK Red Off All AC OK LEDs Off AC OK Off Off Power Off or Failure...

Страница 22: ...LED Condition Status PS1 PS2 Power Supply Status Green Power supply is operating normally It is installed properly and the power cord is attached to a power source Amber Power supply fault The power supply may not be installed properly Off Power off or failure Diag Diagnostic Flashing Green System self diagnostic test in progress Green System self diagnostic test successfully completed Amber Syste...

Страница 23: ...s TABLE 13 Power status LEDs LED Condition Status DC OK Green DC output ok Red DC output fail AC OK Green AC input ok Off AC input fail TABLE 14 Switch status for two installed power supply units State LED PSU1 PSU2 Switch Status Redundancy Four Green PSU LEDs AC OK Green Green Running Yes DC OK Green Green Single Red DC OK LED AC OK Green Green Running No DC OK Green Red Both DC OK LEDs Red AC OK...

Страница 24: ...lling and replacing a power supply refer to Installing and replacing a power supply unit on page 26 For information on LED status refer to Table 9 FIGURE 16 PowerConnect B FCX624s and PowerConnect B FCX648s AC power supply receptacle FIGURE 17 PowerConnect B FCX624 and PowerConnect B FCX648 AC power supply receptacle Power supply unit operation When only one PSU is installed both AC OK and DC OK L...

Страница 25: ...er cords C13 C14 for AC sourced devices PowerConnect B FCXs devices ship with a 5M CX 4 stacking cable Rack mount kit Document Kit Rubber feet Kt Retainer nuts and screws Warranty card A straight through EIA or TIA DB 9 serial cable F F If you prefer to build your own cable see the pinout information in Attaching a PC or terminal on page 25 General requirements To manage the system you need a mana...

Страница 26: ...C to the Dell device This will enable you to configure the device through the Command Line Interface CLI Attaching a PC or terminal on page 25 6 No default password is assigned to the CLI For additional access security assign a password Assigning permanent passwords on page 33 7 Before attaching equipment to the device you need to configure an interface IP address to the subnet on which it will be...

Страница 27: ...Make sure the air flow around the front and sides of the device is not restricted CAUTION Never leave tools inside the device Lifting precautions CAUTION Make sure the rack or cabinet housing the device is adequately secured to prevent it from becoming unstable or falling over Power precautions CAUTION Use a separate branch circuit for each AC power cord which provides redundancy in case one of th...

Страница 28: ...infrastructure Ensure that the proper cabling is installed at the site Refer to Hardware Specifications on page 57 for a summary of supported cabling types and their specifications Installation location Before installing the device plan its location and orientation relative to other devices and equipment Switches can be mounted in a standard 19 inch equipment rack that meets EIA 310D standards or ...

Страница 29: ...er nuts and screws provided CAUTION Make sure the rack or cabinet housing the device is adequately secured to prevent it from becoming unstable or falling over Desktop installation FIGURE 18 Attaching the adhesive feet 1 Attach the four adhesive feet to the bottom of the first switch 2 Set the device on a flat desktop table or shelf near an AC power source Make sure that adequate ventilation is pr...

Страница 30: ... Environment on page 57 Mechanical loading Do not place any equipment on top of a rack mounted unit Circuit overloading Be sure that the supply circuit to the rack assembly is not overloaded Grounding Rack mounted equipment should be properly grounded Particular attention should be given to supply connections other than direct connections to the mains Use the following setps to mount devices in ra...

Страница 31: ...GURE 21 Installing the device in a rack 4 If installing a single switch only proceed to Powering on the system on page 24 5 If installing multiple switches mount them in the rack one below the other in any order Connecting devices in a stack PowerConnect B FCX624s and PowerConnect B FCX648s devices Figure 5 shows how the stack cables are connected between switches in a stack The connection is base...

Страница 32: ... can form a stack containing up to eight PowerConnect B FCX units To connect switches in a stack perform the following steps 1 Plug one end of a stack cable into one of the CX4 stacking ports of the top unit 2 Plug the other end of the stack cable into one of the stacking ports of the next unit 3 Repeat steps 1 and 2 for each unit in the stack Form a simple chain starting with a stacking port on t...

Страница 33: ...gure the default stacking ports on the other PowerConnect B FCX device For more information see the FastIron Configuration Guide You can form a stack containing up to eight PowerConnect B FCX624 and PowerConnect B FCX648 units To connect switches in a stack perform the following steps 1 Plug one end of an LC LC MM Fiber cable into one of the SFP stacking ports of the top unit 2 Plug the other end ...

Страница 34: ...C connector on the rear panel 3 Insert the power cable plug into a 115V 120V or 240V outlet 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 Reset 1 PS 2 Diag Console Mgmt 25 27 29 31 33 35 37 39 41 43 45 47 26 28 30 32 34 36 38 40 42 44 46 48 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 Reset 1 PS 2 Diag Console Mgmt 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 ...

Страница 35: ...FCX Series Configuration Guide Access the CLI by attaching a serial cable to the Console port After you assign an IP address you can access the system through Telnet the Web management interface or Brocade Network Advisor Use the following steps to attach a management station to the serial port 1 Connect a PC or terminal to the serial port of the system using a straight through cable The serial po...

Страница 36: ...in Table 16 some of the wires should not be connected Installing and replacing a power supply unit CAUTION For the PowerConnect B FCX624 and PowerConnect B FCX648 devices be sure that the airflow direction of the power supply unit matches that of the installed fan tray The power supplies and fan trays are clearly labeled with either a green arrow with an E or an orange arrow with an I as shown in ...

Страница 37: ...l recommends using an ESD wrist strap during installation 3 Remove the PSU from the anti static shielded bag 4 Holding the PSU level guide it into the carrier rails on each side and gently push it all the way into the slot ensuring that it firmly engages with the connector 5 When you are sure the PSU has properly engaged the connector tighten the retainer screws to secure the in PSU the slot When ...

Страница 38: ...strap during installation 3 Remove the fan tray from the anti static shielded bag 4 Holding the fan tray level guide it into the carrier rails on each side and gently push it all the way into the slot ensuring that it firmly engages with the connector 5 When you are sure the fan tray has properly engaged the connector tighten the retainer screws to secure the fan tray in the slot NOTE The fans are...

Страница 39: ...ewdriver 2 Before opening the package that contains the new fan tray touch the bag to the switch casing to discharge any potential static electricity It is recommended that you wear an ESD wrist strap during installation 3 Remove the fan tray from the anti static shielded bag 4 Holding the fan tray level guide it into the carrier rails on each side and gently push it all the way into the slot ensu...

Страница 40: ...odule touch the bag to the switch casing to discharge any potential static electricity It is recommended that you wear an ESD wrist strap during installation 3 Remove the module from the anti static shielded bag 4 Holding the module level guide it into the carrier rails on each side and gently push it all the way into the slot ensuring that it firmly engages with the connector 5 When you are sure ...

Страница 41: ...these steps to install an optional module 1 Remove the blank metal plate or a installed module from the slot by removing the two screws with a Phillips screwdriver 2 Before opening the module package touch the bag to the switch casing to discharge any static electricity It is recommended that you wear an ESD wrist strap during installation 3 Remove the module from the anti static shielded bag 4 Ho...

Страница 42: ...3 1002267 01 Installing an optional module in PowerConnect B FCX624 and PowerConnect B FCX648 devices 2 CAUTION If you do not install a module in a slot you must keep the slot panel in place If you run the device with an uncovered slot the system will overheat ...

Страница 43: ...ystem or port parameters Privileged EXEC This level is also called the Enable level and can be secured by a password You can perform tasks such as manage files on the flash module save the system configuration to flash and clear caches at this level CONFIG The configuration level This level lets you configure the system IP address and configure switching and routing features To access the CONFIG m...

Страница 44: ...r to Recovering from a lost password on page 34 Syntax enable super user password read only password port config password text Passwords can be up to 32 characters long Recovering from a lost password By default the CLI does not require passwords However if someone has configured a password for the device but the password has been lost you can regain super user access to the device using the follo...

Страница 45: ...ces running Layer 2 software Use the following procedure to configure an IP Address on a device running Layer 2 software 1 At the opening CLI prompt enter enable PowerConnect enable 2 Enter the following command at the Privileged EXEC level prompt for example PowerConnect then press Enter This command erases the factory test configuration if still present PowerConnect erase startup config CAUTION ...

Страница 46: ...mand at the CLI Privileged EXEC level prompt then press Enter This command erases the factory test configuration if still present PowerConnect erase startup config CAUTION Use the erase startup config command only for new systems If you enter this command on a system you have already configured the command erases the configuration If you accidentally do erase the configuration on a configured syst...

Страница 47: ...sk enter the mask in IP address format For example enter 209 157 22 99 255 255 255 0 for an IP address with a Class C subnet mask To enter a prefix network mask enter a forward slash and the number of bits in the mask immediately after the IP address For example enter 209 157 22 99 24 for an IP address that has a network mask with 24 significant bits ones By default the CLI displays network masks ...

Страница 48: ... the virtual interface to enable the Layer 3 switch to route protocol traffic from one Layer 3 VLAN to the other without using an external router This section describes how to configure an IP address on a virtual interface NOTE The switch uses the lowest MAC address on the device the MAC address of port 1 or 1 1 1 as the MAC address for all ports within all virtual interfaces you configure on the ...

Страница 49: ...For copper connections to Ethernet hubs a 10 100BaseTX or 1000BaseT switch or another Dell device a crossover cable is required Figure 32 and Figure 33 If the hub is equipped with an uplink port it will require a straight through cable instead of a crossover cable NOTE The 802 3ab standard automatic MDI or MDIX detection calls for automatic negotiation of the connection between two 1000Base T port...

Страница 50: ...he port as an MDI port or designate the port as an MDIX port For more information about this feature and how configure it refer to PowerConnect B FCX Series Configuration Guide Connecting a network device to a fiber port For direct attachment from the device to a Gbps NIC switch or router using a fiber optic transceiver you will need fiber cabling with an LC connector To connect the device to anot...

Страница 51: ...transceiver 1 Put on the ESD wrist strap and ground yourself by attaching the clip end to a metal surface such as an equipment rack to act as ground 2 Remove the new transceiver from the protective packaging 3 Gently insert the transceiver into the slot until it clicks into place Transceivers are keyed to prevent incorrect insertion TABLE 17 Supported XFP transceivers for PowerConnect B FCX624s an...

Страница 52: ...covering from the fiber optic port connectors and store the covering for future use 2 Before cabling a fiber optic transceiver Dell strongly recommends cleaning the cable connectors and the port connectors For more information refer to Cleaning the fiber optic connectors on page 43 3 Gently insert the cable connector a tab on each connector should face upward into the transceiver connector until t...

Страница 53: ...ice through the network enter a command similar to the following at any level of the CLI PowerConnect ping 192 33 4 7 Syntax ping ip addr source ip addr count num timeout msec ttl num verify no fragment quiet data 1 to 4 byte hex e g abcdef00 numeric size byte brief max print per sec num 0 2047 NOTE If you address the ping to the IP broadcast address the device lists the first four responses Obser...

Страница 54: ...d with the remote port You can do the following Verify that the connection to the other network device has been properly made Also make certain that the other network device is powered on and operating correctly Verify that the transmit port on the Dell device is connected to the receive port on the other network device and that the receive port on the Dell device is connected to the transmit port...

Страница 55: ...e connection to the other network device has been properly made Also make certain that the other network device is powered on and operating correctly Verify that the transmit port on the Dell device is connected to the receive port on the other network device and that the receive port on the Dell device is connected to the transmit port on the other network device If you are not certain remove the...

Страница 56: ...erred to as Time Domain Reflectometry TDR By examining the reflection the device can detect and report cable statistics such as local and remote link pair cable length and link status Configuration notes This feature is supported on copper ports only It is not supported on fiber ports The port to which the cable is connected must be enabled when you issue the command to diagnose the cable If the p...

Страница 57: ...sholds For more information about digital optical monitoring refer to PowerConnect B FCX Series Configuration Guide TABLE 20 Cable statistics This Line Displays Port The port that was tested Speed The current line speed of the port Local pair The local link name Pair Length The cable length when terminated or the distance to the point of fault when the line is not up Remote pair The remote link na...

Страница 58: ...48 PowerConnect B FCX Switch Hardware Installation Guide 53 1002267 01 Troubleshooting network connections 3 ...

Страница 59: ...ure equals or exceeds the shutdown temperature for five consecutive polls by the software the software will reboot the device to prevent damage You can use the CLI or Web management interface to perform the following tasks Display the temperature of the device Change the warning and shutdown temperature levels Change the device poll time Displaying the temperature By default the software polls the...

Страница 60: ...itical D debugging M emergency E error I informational N notification W warning Static Log Buffer Dynamic Log Buffer 50 entries at 0 days 0 hours 2 minutes 0 seconds level alert Temperature 48 0 C degrees warning level 45 0 C degrees shutdown level 55 0 C degrees at 0 days 0 hours 1 minutes 0 seconds level alert Temperature 40 0 C degrees warning level 35 0 C degrees shutdown level 45 0 C degrees ...

Страница 61: ...g the shutdown temperature You can change the shutdown temperature using the fan threshold command as shown The valid range is 0 125 deg C PowerConnect config stack unit 1 PowerConnect config unit 1 fan threshold mp speed 3 62 95 PowerConnect config unit 1 show chassis The stack unit 1 chassis info Power supply 1 NA AC Regular present status ok Power supply 2 not present Fan ok speed auto 1 2 3 Fa...

Страница 62: ...eg C Shutdown level 80 0 deg C CPU Temperature Readings Current temperature 47 5 deg C Enter a command to the following to change the temperature shutdown level from 80 deg C to 90 deg C PowerConnect stack unit 1 PowerConnect config unit 1 fan threshold mp speed 3 50 90 Syntax fan threshold speed 3 mp lowest value highest value The value can be 0 125 Enter the show chassis command to confirm the c...

Страница 63: ...ddress entry in all VLANs For example to remove entries for the MAC address 000d cb80 00d in all VLANs enter the following command at the Privileged EXEC level of the CLI PowerConnect clear mac address 000d cb80 00d0 Syntax clear mac address mac address ethernet port num vlan number If you enter the clear mac address command without any parameters the software removes all MAC entries Use the mac a...

Страница 64: ...ptic module Removing a copper or fiber optic module You can remove a copper or fiber SFP also called a mini GBIC from a slot while the PowerConnect B FCX is powered on and running While removing a copper or fiber optic module be sure to wear an ESD wrist strap with a plug for connection to the ESD connector on the PowerConnect B FCX CAUTION For safety reasons the ESD wrist strap should contain a s...

Страница 65: ...or fiber optic module out of the port FIGURE 38 Remove fiber optic module 5 Store the copper or fiber optic module in a safe static free place or in an anti static bag 6 Install a new copper or fiber optic module in the port Cabling a fiber optic module For instructions on cabling a fiber optic module refer to Cabling a fiber optic transceiver on page 42 Cleaning the fiber optic connectors For ins...

Страница 66: ...56 PowerConnect B FCX Switch Hardware Installation Guide 53 1002267 01 Replacing a copper or fiber optic module 4 ...

Страница 67: ...following environmental conditions Operating Environment Table 22 provides the operating environment specifications TABLE 21 Physical dimensions and weight Model Height Width Depth Weight PowerConnect B FCX624s PowerConnect B FCX648s 4 4 cm 1 7 in 44 cm 17 32 in 38 6 cm 15 19 in 4 kg 8 8 lbs PowerConnect B FCX624 4 4 cm 1 7 in 44 cm 17 32 in 43 5 cm 17 13 in 5 35 kg 11 79 lbs PowerConnect B FCX648...

Страница 68: ... A NOTE Operating noise is based on the ISO 7779 standard Figure 39 shows the airflow for the PowerConnect B FCX624s and PowerConnect B FCX648s models Figure 40 shows airflow for PowerConnect B FCX624 E and PowerConnect B FCX648 E devices and Figure 41 shows airflow for PowerConnect B FCX624 I and PowerConnect B FCX648 I devices CAUTION For the PowerConnect B FCX624E PowerConnect B FCX624I PowerCo...

Страница 69: ...RE 39 PowerConnect B FCX624s and PowerConnect B FCX648s device airflow FIGURE 40 PowerConnect B FCX624 E and PowerConnect B FCX648 E device airflow 1 2 1 Air Inflow 2 Air outlet 1 Air Inflow 2 Air outlet Diag Rese t PS 1 2 Mgmt Cons ole 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 1 2 ...

Страница 70: ...s 5 FIGURE 41 PowerConnect B FCX624 I and PowerConnect B FCX648 I device airflow For a complete list of regulatory compliances refer to Regulatory compliance on page 69 1 Air Inflow 2 Air outlet Diag Rese t PS 1 2 Mgmt Cons ole 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 1 2 ...

Страница 71: ...her a DB 9 or DB 25 connector male or female Serial cable options between the PowerConnect B FCX switch and a PC or terminal are shown in Figure 43 NOTE As indicated in Figure 43 and Figure 44 some of the wires should not be connected If you do connect the wires that are labeled Reserved you may get unexpected results with some terminals FIGURE 43 Console port pin assignments showing cable connect...

Страница 72: ...1 1 8 RD RD TD Not used TD Not used Not used Not used RD RD TD CMT TD CMT CMT CMT Pin Assignment MDI X ports MDI X ports 10BaseT Pin Number 100BaseTX and 1000BaseT TABLE 24 Cable length summary Cable Type Connector Type Core Diameter microns Modal Bandwidth MHz km or Wavelength nm Range meters 1000Base BX D Single mode Fiber SMF LC connector for SFP module 9 1490 nm 2 10000 10km 1000Base BX U SMF ...

Страница 73: ...F LC connector for SFP module 62 5 500 up to 2000 2 km 100Base FX IR MMF SC 62 5 125 2 km 1 24 miles 100Base FX LR SMF SC 9 125 20 km 12 43 miles 10GBase CX4 Infiniband 4x copper XAUI connector n a n a up to 15 10G SFP TWNX SFP n a n a up to 15 TABLE 24 Cable length summary Continued Cable Type Connector Type Core Diameter microns Modal Bandwidth MHz km or Wavelength nm Range meters TABLE 25 AC po...

Страница 74: ...64 PowerConnect B FCX Switch Hardware Installation Guide 53 1002267 01 Hardware specifications 5 ...

Страница 75: ...alfunctioning such as the power cord or network cabling test them in an alternate environment where you are sure that all the other components are functioning properly TABLE 26 Troubleshooting chart Symptom Action Power LED is Off Internal power supply is disconnected Check connections between the switch the power cord and the wall outlet Contact Technical Support Power LED is Amber Internal power...

Страница 76: ...e However you must first configure the switch with a valid IP address subnet mask and default gateway If you have trouble establishing a link to the management agent check to see if you have a valid network connection Then verify that you entered the correct IP address Also be sure the port through which you are connecting to the switch has not been disabled If it has not been disabled then check ...

Страница 77: ...erence to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CAUTION Changes or modifications made to this device which are not expressly approved by Dell could void the user s authority to operate the equipment Industry Canada statement Cet appareil nu...

Страница 78: ...required to take corrective actions Japan power cord English translation of above statement ATTENTION Never use the power cord packed with your equipment for other products Korea Class A statement English Translation of Above Statement Class A device Broadcasting Communication Device for Office Use This device obtained EMC registration for office use Class A and may be used in places other than ho...

Страница 79: ...for the PowerConnect B FCX family of switches TABLE 27 Regulatory Compliance and Safety Approvals Certifications Emissions ICES 003 Electromagnetic Emission FCC Part 15 Class A EN 55022 CISPR 22 Class A VCCI Class A EN 61000 3 2 Power Line Harmonics EN 61000 3 3 Voltage Fluctuation Flicker EN 61000 6 3 Electromagnetic Compatibility Generic Standard AS or NZS CISPR 22 Electromagnetic Compatibility ...

Страница 80: ...70 PowerConnect B FCX Switch Hardware Installation Guide 53 1002267 01 Regulatory compliance A ...

Страница 81: ...rno en el que la temperatura ambiente de operación pueda exceder los 40 C 104 F CAUTION Make sure the air flow around the front sides and back of the device is not restricted VORSICHT Stellen Sie sicher dass an der Vorderseite den Seiten und an der Rückseite der Luftstrom nicht behindert wird MISE EN GARDE Vérifiez que rien ne restreint la circulation d air devant derrière et sur les côtés du disp...

Страница 82: ...los circuitos de suministros añada las capacidades nominales de corriente amp de todos los instrumentos instalados en el mismo circuito que el instrumento Compare esta suma con el límite nominal para el circuito Las capacidades nominales de corriente máximas están generalmente impresas en los instrumentos cerca de los conectores de corriente de entrada CAUTION Use the erase startup config command ...

Страница 83: ...nunca herramientas en el interior del chasis CAUTION Changes or modifications made to this device that are not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment VORSICHT Falls dieses Gerät verändert oder modifiziert wird ohne die ausdrückliche Genehmigung der für die Einhaltung der Anforderungen verantwortlichen Partei einzuholen ka...

Страница 84: ... utilisent des lasers de classe 1 PELIGRO Todas las interfaces de fibra óptica utilizan láser de clase 1 DANGER Make sure the rack or cabinet housing the device is adequately secured to prevent it from becoming unstable or falling over GEFAHR Stellen Sie sicher dass das Gestell oder der Schrank für die Unterbringung des Geräts auf angemessene Weise gesichert ist so dass das Gestell oder der Schran...

Страница 85: ...nd zuständig ist Das Siegel ist Ihre Garantie dass das Stromkabel sicher mit Ihrem Gerät verwendet werden kann DANGER Si l installation nécessite un cordon d alimentation autre que celui fourni avec le dispositif assurez vous d utiliser un cordon d alimentation portant la marque de l organisation responsable de la sécurité qui définit les normes et régulations pour les cordons d alimentation dans ...

Страница 86: ...76 PowerConnect B FCX Switch Hardware Installation Guide 53 1002267 01 Danger notices B ...

Отзывы: