1-10
Dell PowerEdge 2100/180 and 2100/200 Systems Service Manual
System Unit
The following subsections provide service-related information about the
computer.
System Power Supply
The 230-W system power supply can operate from an AC power source of
115 VAC at 60 Hz or 230 VAC at 50 Hz. The system power supply provides the
DC operating voltages and currents listed in Table 1-1.
NOTE: The power supply produces DC voltages only under its loaded condi-
tion. Therefore, when you measure these voltages, the DC power connectors
must be connected to their corresponding power input connectors on the system
board or drives.
.
Pin Assignments for the DC Power Connectors
The power-supply output voltages can be measured at the back (wire side) of
the connectors without disconnecting them. Figures 1-6, 1-7, and 1-8 show the
wire side of the connectors.
Table 1-1. DC Voltage Ranges
Voltage
Range
Maximum Output
Current
1
+3.3 VDC
+3.15 to +3.45 VDC
14.0 A
+5 VDC
+4.75 to +5.25 VDC
29.0 A
+12 VDC
+11.40 to +12.60 VDC
6.0 A
2
–12 VDC
–10.80 to –13.20 VDC
0.3 A
–5 VDC
–4.50 to –5.50 VDC
0.3 A
+5 VFP
3
+4.75 to +5.25 VDC
10 mA
1
Maximum continuous DC output power shall not exceed 230 W. Maximum combined load on
+5 VDC and +3.3 VDC shall not exceed 170 W.
2
The total power of all voltages other than +12 VDC must not exceed 158 W.
3
VFP (volts flea power) — sometimes called “standby power.”
Содержание Inspiron 2100
Страница 2: ......
Страница 3: ... Dell PowerEdge 2100 180 and 2100 200 Systems SERVICE MANUAL ...
Страница 11: ...xiv DELL CONFIDENTIAL Preliminary 4 19 00 ...
Страница 16: ...ix ...
Страница 39: ...1 22 Dell PowerEdge 2100 180 and 2100 200 Systems Service Manual ...
Страница 51: ...3 6 Dell PowerEdge 2100 180 and 2100 200 Systems Service Manual ...
Страница 72: ......
Страница 73: ... Printed in the U S A P N 82502 ...