Warning:
Make sure the voltage of your power source is compatible with the voltage rating of the BPS. If the
power source voltage is too low, the BPS will not activate. If the voltage is too high, the BPS can be
destroyed.
To connect a BPS power module to a power source, follow these steps:
1. Obtain a power cable with a C13 connector and a connector that fits the receptacle of your power source, in
addition to a hook-and-loop fastener provided in the BPS shipping box.
If power cables are not in the shipping box, see your PS Series support provider or reseller for power cable
information.
2. Open the latch for the C14 input connector on the power module (on the right side of the power module) and
insert the cable’s C13 connector. See
.
3. Connect the power cable to a power source.
4. Use the hook-and-loop fastener strip to secure the power cable to the latch on the power module. This
provides strain relief for the cable. See
.
Figure 27: Connecting a BPS Power Module to a Power Source
30
EqualLogic FS7500 Installation and Setup
3 Power Connections