EqualLogic FS7500 Installation and Setup
2 Hardware Rack Mounting
The battery in a BPS is installed backwards in the factory to preserve power during shipment. You must remove
the battery from each power module, turn it around, and reinsert it to complete the circuit for proper operation.
Perform these steps for each power module:
1. Locate the module cover lever on the right side of the module. See Callout 1 in
2. Simultaneously, slide the cover latch to the left, grasp the hand-holds on the module and gently pull the right
side of the cover from the chassis (callout 2), and then slide the cover to the right to disengage it from the
module (callout 3).
Make sure not to pull on the ribbon cable or disconnect it.
Figure 15: Removing the Module Cover
3. Grasp the plastic handle labeled PULL HERE on the battery inside the module and slowly remove the
battery. See
.
Warning:
For safety, do not allow the power module front cover to come in contact with the battery pack during
removal.