Data network A, nodes 1 - 22 cabling example
Use the following figure and table to connect cables for the data network A, nodes 1 -
22. The node ports referred to in this table are 10 G ports.
Note
In this example, data switch ports have been intentionally left empty. These empty
ports can be used for other user-allocated purposes. If no other use is required for the
empty ports, nodes may be connected to the data switches without leaving empty
ports. However, ensure that on each node, each NIC is connected to a different data
switch (either Data Switch A or Data Switch B), in order to prevent a single point of
failure in case a switch fails.
Figure 22 Data networks A and B cabling example
Node 1
Data Switch A
Node 16
Mgmt Server
40 G link to
core switch
40 G link to
core switch
40 G link to
core switch
40 G link to
core switch
2
4
0
1
0
48
Data Switch B
25
27
48
2
Table 13 Data A, nodes 1 - 22 cabling
Source
Destination
Node 1 Onboard Port 0
Data Switch A Port 2
Node 2 Onboard Port 0
Data Switch A Port 6
Install Data Network I/O Cables
56
Hardware Installation Guide
Содержание EMC VxFlex Ready Node 14G
Страница 1: ...Dell EMC VxFlex Ready Node 14G Hardware Installation Guide 302 004 321 REV 03 ...
Страница 6: ...FIGURES 6 Hardware Installation Guide ...
Страница 8: ...TABLES 8 Hardware Installation Guide ...
Страница 16: ...Before You Begin 16 Hardware Installation Guide ...
Страница 18: ...1U1N Procedures 18 Hardware Installation Guide ...
Страница 40: ...1U1N Configuration Equipment Installation 40 Hardware Installation Guide ...
Страница 48: ...Install AC Power Cables 48 Hardware Installation Guide ...
Страница 62: ...2U1N Procedures 62 Hardware Installation Guide ...
Страница 74: ...2U1N Configuration Equipment Installation 74 Hardware Installation Guide ...