Figure 59. Removing the external cooling fan
Next steps
1
Follow the procedure listed in
After working inside your system
.
2
Install the air shroud.
Related link
Installing the external cooling fan
Prerequisites
CAUTION:
Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple
repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage
due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are
shipped with your product.
1
Follow the safety guidelines listed in
2
Follow the procedure listed in
Before working inside your system
.
Steps
1
Route the external cooling fan power cable into the system through the slot at the back of the chassis.
2
Align and insert the lower and upper hooks on the external cooling fan into the corresponding slots at the back of the chassis.
3
Use the four screws to secure the external cooling fan to the chassis.
4
Connect the external cooling fan power cable to the FAN2 connector on the system board.
Dell EMC PowerEdge T440 Installation and Service Manual
Installing and removing system components
111