Table 15 Redundant AC PSU status indicator (continued)
Convention Power
Indicator
Pattern
Condition
PSU to make a matched pair can result in an error
condition and unexpected system shutdown. To change
from a High Output configuration to a Low Output
configuration or vice versa, you must turn off the system.
CAUTION
AC PSUs support both 220 V and 110 V input
voltages with the exception of Titanium PSUs, which
support only 220 V. When two identical PSUs receive
different input voltages, they can output different
wattages, and trigger a mismatch.
CAUTION
If two PSUs are used, they must be of the same
type and have the same maximum output power.
CAUTION
Combining AC and DC PSUs is not supported
and triggers a mismatch.
E
Not lit
Power is not connected.
Non-redundant power supply unit indicator codes
Press the self-diagnostic button to perform a quick health check on the non-redundant power
supply unit (PSU) of the system.
Figure 15 Non-redundant AC PSU status indicator and self-diagnostic button
1. self-diagnostic button
2. AC PSU status indicator
This table describes about non-redundant AC PSU status indicator.
Table 16 Non-redundant AC PSU status indicator
Power Indicator
Pattern
Condition
Not lit
Power is not connected or PSU is faulty.
Dell PowerEdge R430 system overview
34
Dell PowerEdge R430 Owner's Manual
Содержание E28S Series
Страница 1: ...Dell PowerEdge R430 Version 1 Owner s Manual E28S Series A03 ...
Страница 8: ...Contents 8 Dell PowerEdge R430 Owner s Manual ...
Страница 36: ...Dell PowerEdge R430 system overview 36 Dell PowerEdge R430 Owner s Manual ...
Страница 40: ...Documentation resources 40 Dell PowerEdge R430 Owner s Manual ...
Страница 194: ...Using system diagnostics 194 Dell PowerEdge R430 Owner s Manual ...
Страница 200: ...Jumpers and connectors 200 Dell PowerEdge R430 Owner s Manual ...
Страница 216: ...Troubleshooting your system 216 Dell PowerEdge R430 Owner s Manual ...
Страница 220: ...Getting help 220 Dell PowerEdge R430 Owner s Manual ...