omconfig: Managing Components Using the Instrumentation Service
Severity
In the context of configuring events, severity determines how severe an event must be before Server
Administrator notifies you of the event for a component type. When there are multiple components of
the same type in the same system chassis, you can also specify whether you want to be notified for event
severity according to the number of the component by using the index=
<n>
parameter. Table 4-26 shows
the valid severity parameters.
Index
Index refers to the number of an event for a particular component. Index is an optional parameter.
When you omit the index parameter, events are configured for all components of the specified type, such
as all fans. When a system contains more than one fan, for example, you can enable or disable event
notification for a particular fan. An example command is as follows:
omconfig system events type=fan index=0 severity=critical
As a result of the example command, Server Administrator will send an SNMP trap only when the first
fan in the system chassis (index 0) has reached critical fan RPMs.
omconfig system webserver
Use the
omconfig system webserver
command to start or stop the Web server. Table 4-27 shows the valid
parameters for the command.
Table 4-26.
System Event Severity Parameters
Command
Result
Description
omconfig system events type=<
component
name
>
severity=info
Enables notification for
informational, warning,
and critical events.
Least restrictive form of event
notification.
omconfig system events type=<
component
name
>
severity=warning
Enables notification for
warning and critical
events.
Omits informational event
notification, for example, when a
component returns to normal status.
omconfig system events type=<
component
name
>
severity=critical
Enables notification for
critical events only.
Restrictive form of event
notification.
omconfig system events type=<
component
name
>
severity=none
Disables event
notification.
No event notification.
Table 4-27.
Web Server Configuration Parameters
name=value pair
Description
action=start
Starts the Web server.
action=stop
Stops the Web server.
action=restart
Restarts the Web server.
Содержание Command Line Interface
Страница 12: ...12 Contents ...
Страница 50: ...50 omreport Viewing System Status Using the Instrumentation Service ...
Страница 100: ...100 omconfig Managing Components Using the Instrumentation Service ...
Страница 118: ...118 omreport rac Viewing Remote Access Controller Components ...
Страница 134: ...134 omconfig rac Managing the Remote Access Controller ...
Страница 186: ...186 Using the Storage Management Service ...
Страница 214: ...214 Glossary ...