omconfig: Managing Components Using the Instrumentation Service
93
omconfig system platformevents
Use the
omconfig system platformevents
command to configure shutdown action, if any, to be taken for a
specific platform event. You can also enable or disable platform event filter alert generation.
NOTICE:
If you set a platform event shutdown action to anything other than "none", your system will forcefully
shutdown when the specified event occurs. This shutdown is initiated by firmware and is carried out without first
shutting down the operating system or any of the applications running on your system.
Table 4-23 shows the valid parameters for the command.
NOTE:
Alert settings are mutually exclusive and can be set one at a time only. The action settings are also mutually
exclusive and can be set one at a time only. However, alert and action settings are not mutually exclusive of
each other.
Table 4-24 lists the components and the events for which you can set platform events. Components are
listed in alphabetical order, except that warning events always precede failure events for a component.
Table 4-23.
Shutdown Action
Shutdown Action
Description
alert=disable
Disables the SNMP alert.
alert=enable
Enables the SNMP alert to be sent.
action=none
Takes no action when the system is hung or has crashed.
action=powercycle
Turns the electrical power to the system off, pauses, turns the power on, and
reboots the system.
action=poweroff
Turns off the electrical power to the system.
action=reboot
Forces the operating system to shut down and initiates system startup,
performs BIOS checks, and reloads the operating system.
Table 4-24.
omconfig system platformevents
Event Name
Description
alertsenable=true | false
true
: Enables generation of platform event filter alerts.
false
: Disables generation of platform event filter alerts.
NOTE:
This setting is independent of the individual platform event filter alert settings.
For a platform event filter to generate an alert, both the individual alert and the global
event alert must be enabled.
event=batterywarn
Sets action or enables/disables alert generation when a battery device detects that
the battery is pending a failure condition.
event=batteryfail
Sets action or enables/disables alert generation when a battery device detects that
the battery has failed.
event=discretevolt
Sets action or enables/disables alert generation when a discrete voltage probe
detects that the voltage is too low for proper operation.
Содержание Command Line Interface
Страница 12: ...12 Contents ...
Страница 50: ...50 omreport Viewing System Status Using the Instrumentation Service ...
Страница 100: ...100 omconfig Managing Components Using the Instrumentation Service ...
Страница 118: ...118 omreport rac Viewing Remote Access Controller Components ...
Страница 134: ...134 omconfig rac Managing the Remote Access Controller ...
Страница 186: ...186 Using the Storage Management Service ...
Страница 214: ...214 Glossary ...
Страница 226: ...26 Index 226 Index ...