164
Using the Storage Management Service
omconfig Unassign Dedicated Hot Spare
Use the following
omconfig
command syntax to unassign one or more physical disks that were previously
assigned as a hot spare to a virtual disk.
Complete Syntax
omconfig storage vdisk action=assigndedicatedhotspare controller=id
vdisk=id pdisk=<PDISKID> assign=no
where
id
is the controller ID and virtual disk ID. The
<PDISK>
variable specifies the physical disk.
To obtain the values for the controller, virtual disk, and physical disk, enter
omreport storage controller
to display the controller IDs and then enter
omreport storage vdisk controller=ID
and
omreport storage
pdisk controller=ID
to display the IDs for the virtual disks and physical disks attached to the controller.
Example Syntax
In this example, you are unassigning physical disk 3 on connector 0 of controller 1 as a dedicated hot
spare to virtual disk 4. On a SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers:
To unassign the dedicated hot spare described in this example, enter:
omconfig storage vdisk action=assigndedicatedhotspare controller=1
vdisk=4 pdisk=0:3 assign=no
Example for SAS Controllers:
To unassign the dedicated hot spare described in this example, enter:
omconfig storage vdisk action=assigndedicatedhotspare controller=1
vdisk=4 pdisk=0:2:3 assign=no
omconfig Check Consistency
Use the following
omconfig
command syntax to initiate a check consistency on a virtual disk. The check
consistency task verifies the virtual disk’s redundant data.
Complete Syntax
omconfig storage vdisk action=checkconsistency controller=id vdisk=id
where
id
is the controller ID and virtual disk ID as reported by the
omreport
command. To obtain these
values, enter
omreport storage controller
to display the controller IDs and then enter
omreport storage
vdisk controller=ID
to display the IDs for the virtual disks attached to the controller.
Example Syntax
For example, to run a check consistency on virtual disk 4 on controller 1, enter:
omconfig storage vdisk action=checkconsistency controller=1 vdisk=4
Содержание Command Line Interface
Страница 12: ...12 Contents ...
Страница 50: ...50 omreport Viewing System Status Using the Instrumentation Service ...
Страница 100: ...100 omconfig Managing Components Using the Instrumentation Service ...
Страница 118: ...118 omreport rac Viewing Remote Access Controller Components ...
Страница 134: ...134 omconfig rac Managing the Remote Access Controller ...
Страница 186: ...186 Using the Storage Management Service ...
Страница 214: ...214 Glossary ...