Icon
Description
Condition
Corrective action
card experiences an
error.
NOTE:
For more information about the supported PCIe cards, see
Expansion card installation guidelines.
Memory
indicator
The indicator turns
solid amber if a
memory error
occurs.
Check the System Event Log or system messages for the location of the
failed memory. Reseat the memory module.
If the problem persists, see
.
Electrical
indicator
The indicator turns
solid amber if the
system experiences
an electrical error
(for example,
voltage out of
range, or a failed
power supply unit
(PSU) or voltage
regulator).
Check the System Event Log or system messages for the specific issue. If it
is due to a problem with the PSU, check the LED on the PSU. Reseat the
PSU.
If the problem persists, see
.
Temperature
indicator
The indicator turns
solid amber if the
system experiences
a thermal error (for
example, the
ambient
temperature is out
of range or there is
a fan failure).
Ensure that none of the following conditions exist:
•
A cooling fan has been removed or has failed.
•
System cover, air shroud, memory module blank, or back filler bracket is
removed.
•
Ambient temperature is too high.
•
External airflow is obstructed.
If the problem persists, see
.
Drive indicator The indicator turns
solid amber if there
is a drive error.
•
Check the System Event Log to determine if the drive has an error.
•
Run the appropriate Online Diagnostics test. Restart the system and run
embedded diagnostics (ePSA).
•
If the drives are configured in a RAID array, restart the system, and
enter the host adapter configuration utility program.
iDRAC Direct LED indicator codes
The iDRAC Direct LED indicator lights up to indicate that the port is connected and is being used as a part of the iDRAC subsystem.
You can configure iDRAC Direct by using a USB to micro USB (type AB) cable, which you can connect to your laptop or tablet. The
following table describes iDRAC Direct activity when the iDRAC Direct port is active:
Dell EMC PowerEdge T640 overview
13
Содержание PowerEdge T640
Страница 23: ...Figure 16 Configuration and layout Dell EMC PowerEdge T640 overview 23 ...
Страница 24: ...Figure 17 Electrical overview 24 Dell EMC PowerEdge T640 overview ...
Страница 25: ...Figure 18 Memory information Dell EMC PowerEdge T640 overview 25 ...
Страница 26: ...26 Dell EMC PowerEdge T640 overview ...