Do not perform a cold startup below 5°C.
•
The operating temperature specified is for a maximum altitude of 3050 m (10,000 ft).
•
150 W/8 core, 165 W/12 core and higher wattage processor [Thermal Design Power (TDP)>165 W] are not supported.
•
Redundant power supply unit is required.
•
Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
•
PCIe SSD is not supported.
•
NVDIMM-Ns are not supported.
•
GPU is not supported.
•
Tape backup unit is not supported.
Thermal restrictions
Following table lists the configuration required for efficient cooling.
Table 33. Thermal restrictions configuration
Configuration
Number of
processors
Heatsink
Processor/DIMM
blank
DIMM
blanks
Type of air
shroud
Fan
PowerEdge
R740
1
One 1U standard heat sink for
CPU ≤ 125 W
Required
Not
required
Standard
Four standard
fans and one
blank to cover
two fan slots
One 2U standard heat sink for
CPU > 125 W
PowerEdge
R740
2
Two 1U standard heat sink for
CPU ≤ 125 W
Not required
Not
required
Standard
Six standard fans
Two 2U standard heat sink for
CPU > 125 W
PowerEdge
R740 with GPU
2
Two 1U high performance
heat sink
Not required
Not
required
GPU air shroud
Six high
performance
fans
Ambient temperature limitations
The following table lists configurations that require ambient temperature less than 35°C.
NOTE:
The ambient temperature limit must be adhered to ensure proper cooling and to avoid excess CPU throttling, which may
impact system performance.
Table 34. Configuration based ambient temperature restrictions
System
Front backplane
CPU Thermal
Design Power
(TDP)
CPU heat sink
Fan type
GPU
Ambient
restriction
PowerEdge
R740
8 x 3.5 inch SAS/
SATA
150 W/8 core, 165
W/12 core, 200
W, 205 W
1U high
performance
High performance
fan
≥1 double-width/
single-width
30°C
8 x 2.5 inch SAS/
SATA
150 W/8 core, 165
W/12 core, 200
W, 205 W
1U high
performance
High performance
fan
≥1 double-width/
single-width
30°C
Technical specifications
41
Содержание PowerEdge R740
Страница 9: ...Figure 1 Supported configurations PowerEdge R740 system overview 9 ...
Страница 27: ...Figure 20 Jumper setting and memory information Figure 21 system task PowerEdge R740 system overview 27 ...
Страница 28: ...Figure 22 NVDIMM battery and mid tray hard drives 28 PowerEdge R740 system overview ...
Страница 141: ...Figure 94 Securing GPU 1 Installing and removing system components 141 ...
Страница 142: ...Figure 95 Installing GPU 2 and 3 142 Installing and removing system components ...