Item
Indicator, button, or
connector
Icon
Description
also configure iDRAC, BIOS, and networking parameters. You can also
launch the virtual Keyboard, Video, and Mouse (KVM) viewer and
virtual Kernel based Virtual Machine (KVM), on a supported mobile
device. For more information, see the Integrated Dell Remote Access
Controller User's Guide at
Status LED indicators
NOTE:
The indicators display solid amber if any error occurs.
Table 5. Status LED indicators and descriptions
Icon
Description
Condition
Corrective action
Drive
indicator
The indicator turns solid amber if
there is a drive error.
•
Check the System Event Log to determine if the drive has an error.
•
Run the appropriate Online Diagnostics test. Restart the system and
run embedded diagnostics (ePSA).
•
If the drives are configured in a RAID array, restart the system, and
enter the host adapter configuration utility program.
Temperature
indicator
The indicator turns solid amber if
the system experiences a thermal
error (for example, the ambient
temperature is out of range or
there is a fan failure).
Ensure that none of the following conditions exist:
•
A cooling fan has been removed or has failed.
•
System cover, air shroud, memory module blank, or back filler bracket is
removed.
•
Ambient temperature is too high.
•
External airflow is obstructed.
If the problem persists, see
Electrical
indicator
The indicator turns solid amber if
the system experiences an
electrical error (for example,
voltage out of range, or a failed
power supply unit (PSU) or voltage
regulator).
Check the System Event Log or system messages for the specific issue. If
it is due to a problem with the PSU, check the LED on the PSU. Reseat the
PSU.
If the problem persists, see
Memory
indicator
The indicator turns solid amber if a
memory error occurs.
Check the System Event Log or system messages for the location of the
failed memory. Reseat the memory module.
If the problem persists, see
PCIe
indicator
The indicator turns solid amber if a
PCIe card experiences an error.
Restart the system. Update any required drivers for the PCIe card. Reinstall
the card.
If the problem persists, see
NOTE:
For more information about the supported PCIe cards, see
Expansion card installation guidelines
.
PowerEdge R740 system overview
13
Содержание PowerEdge R740
Страница 9: ...Figure 1 Supported configurations PowerEdge R740 system overview 9 ...
Страница 27: ...Figure 20 Jumper setting and memory information Figure 21 system task PowerEdge R740 system overview 27 ...
Страница 28: ...Figure 22 NVDIMM battery and mid tray hard drives 28 PowerEdge R740 system overview ...
Страница 141: ...Figure 94 Securing GPU 1 Installing and removing system components 141 ...