Figure 78. Installing a SXM2-GPU heat sink
Next step
1
Install the NVLink air shroud.
Installing the NVLink Air Shroud
Prerequisites
CAUTION:
Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple
repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage
due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are
shipped with your product.
NOTE:
This is a Field Replaceable Unit (FRU). Removal and installation procedures should be performed only by Dell certified
service technicians.
1
Follow the safety guidelines listed in the Safety instructions section.
Steps
1
Align the guide slots on the NVLink air shroud with the screws on the graphics heat sink.
2
Lower the NVLink air shroud into the NVLink board until it is firmly seated.
122
Installing and removing system components