NOTE:
This is a Field Replaceable Unit (FRU). Removal and installation procedures should be performed only by Dell certified
service technicians.
1
Follow the safety guidelines listed in the Safety instructions section.
2
Follow the procedure listed in the Before working inside your system section.
3
Remove the NVLink air shroud.
Steps
1
Using the Phillips #2 screwdriver, loosen one of the screws that secure the SXM2-GPU heat sink to the SXM2 GPU.
2
Loosen the screw diagonally opposite the screw you first removed and repeat the procedure for the remaining two screws.
3
Lift and remove the heat sink from the NVLink board.
Figure 71. Removing SXM2-GPU heat sink
Next step
1
Remove a SXM2 GPU.
Removing an SXM2 GPU
Prerequisites
NOTE:
This is a Field Replaceable Unit (FRU). Removal and installation procedures should be performed only by Dell certified
service technicians.
CAUTION:
To avoid any damage to the SXM2 GPU, ensure that you loosen the screws in a descending order starting from the
screw numbered 8, on the NVLink board.
1
Follow the safety guidelines listed in the Safety instructions section.
2
Follow the procedure listed in the Before working inside your system section.
3
Remove the NVLink air shroud.
Installing and removing system components
115