background image

Page 11

Figure # 1

13. If control has been exposed to water in any way, it must be replaced.
14. Keep combustible material away from gas machine.  Keep burner area clean and free of dust and lint.
15. If gas valve fails to shut off, do not turn off electrical power.  Turn off gas supply allowing water pump to continue

running until system has cooled.  Replace control.

16. The manual valve should not be used to adjust gas flow.
17. All components must be securely mounted with screws, bolts, etc., within the machine.

3 in. 176.2 mm

MINIMUM

3 in. 176.2 mm

MINIMUM

3 in. 176.2 mm

MINIMUM

GAS

VALVE

GAS

VALVE

GAS

VALVE

TUBING

GAS

SUPPLY

DROP

HORIZONTAL

PIPED

GAS

SUPPLY

PIPED

GAS

SUPPLY

DROP

HORIZONTAL

RISER

RISER

ALL BENDS IN METALLIC TUBING SHOULD BE SMOOTH

The following warning applies to installations using L.P., Propane Gas:

 WARNING: To avoid possible injury, fire and explosion, please read and follow these precautions and all instruc-

tions on this machine before lighting the pilot.  This machine uses L.P. (Propane) gas which is heavier

than air and will remain at floor level if there is a leak. Before lighting, sniff at

 

floor level.  If you smell

gas, follow these rules:

a) Get all people out of building.
b)

DO NOT

 light matches. 

 DO NOT

 turn electric lights or switches on or off in area.  

DO NOT

 use an electric fan to

remove gas from area.

c) Shut off gas at L.P. tank outside of building.
d) Phone the gas company and fire department.  Ask for instructions.
Before hanging up, give your name, address, and phone number.  

DO NOT

 go back into the building.  If help is

coming wait for them to arrive.
If your L.P. tank runs out of fuel, turn off gas at the machine.  After L.P. tank is refilled, machine must be re-lit accord-

ing to manufacturer's instructions.  If the gas control has been exposed to 

WATER

 in any way,

 DO NOT

 try to use it. It

must be replaced.  

DO

 

NOT

  attempt repair on gas valve .  It must be replaced.  

DO NOT

 attempt repair on gas

control or machine.  Call an authorized Delco distributor for repairs.

Tampering is DANGEROUS and voids all warranties.

18. Do not short gas valve terminals.  This may burn out the controls.
19. Make certain all wiring connections are tight.  The spark ignitor and electrode connection to the ignition control

must be tight, or damage to the unit may result.

20. The ignition control and pilot burner must both be chassis grounded.
21. Handle the pilot-electrode assembly carefully.  If damaged, replace entire assembly.  The correct spark  gap

should be 7/64" to 1/8".

Содержание Avenger 1000-3 LP

Страница 1: ...Avenger 1000 3 NG LP 2HP Single Phase Operators Manual and Replacement Parts Book Pressure Washers Delco Pressure Washers LIT AVEN 1000 3 DEL...

Страница 2: ...as with all mechanical equipment it requires proper installation operation and maintenance as outlined in this manual The Operators Manual has been written for your benefit For your safety and the saf...

Страница 3: ...90 days whichever is longer Defective parts replaced under this war ranty are the property of DELCO Cleaning Systems LLC 6 All warranty service will be performed by a trained technician employed by an...

Страница 4: ...uctions 6 Operating Instructions 8 Maintenance 9 How to Correct Problems in the Machine 12 Assembly Drawing No 1 15 Assembly Drawing No 2 16 Parts List 17 Assembly Drawing No 3 18 Parts List 19 Assemb...

Страница 5: ...explosion Only fill the fuel tank in an open area Do not fill the tank near open flames or while the unit is running Do not smoke while filling the tank Do not over fill the tank Wipe up any spills T...

Страница 6: ...this machine could result in damage to the machine or injury to the operator or other bystanders Alterations or modifications not authorized by the manufacturer voids any and all warranties and liabi...

Страница 7: ...12 GA 6 P C 193 FT Trigger 50 Wire Braid L51 xW22 1 2 xH51 3 4 625 LBS Flow Rate GPM Pressure Psi Volts Amps Min Circuit Amp Fuel BTUH input Temp Motor Pump Metering Valve Heat Exchanger Coil Spray Co...

Страница 8: ...ING Adequate oxygen is needed for proper combustion or dangerous carbon monoxide can result GAS FIRED UNITS Natural gas units operate on 3 1 2 of water column pressure at the solenoid valve and it mus...

Страница 9: ...or larger Refer to chart on page 4 Electrical CAUTION This machine must be electrically grounded 1 Connect only to grounded outlets with 30 ampere 230 volt a c alternating current 60 Hz single phase...

Страница 10: ...meter B open windows C do not touch electrical switches D extinguish all open flames E immediately call your gas supplier 4 When using L P gas the Control must be equipped with a regulator Make sure t...

Страница 11: ...ell gas follow these rules a Get all people out of building b DO NOT light matches DO NOT turn electric lights or switches on or off in area DO NOT use an electric fan to remove gas from area c Shut o...

Страница 12: ...rk gap 7 64 NOTE When the trigger is released for more than 4 5 minutes the machine will shut off You must turn the control switch to the OFF position then ON to restart The timer is to protect the pu...

Страница 13: ...procedure 1 Locate the oil dipstick in the plug on the top of the pump 2 Turn the oil plug counterclockwise 3 Wipe the dipstick with a clean cloth 4 Screw the dipstick in Pull it back out and check f...

Страница 14: ...he coils is caused by mineral deposits from the water and occurs much faster in hard water areas and with heavier machine usage Lime build up can also be caused by inferior cleaning compounds DANGER F...

Страница 15: ...enance descaling of pops off at relief valve coils High pressure nozzle Remove nozzle at tip of gun and clean Flush There is has been water in the oil and The oil seal is worn Contact an authorized De...

Страница 16: ...ontact an authorized Delco service person V packings Contact an authorized Delco service person The pump is noisy There is air in the suction line Check the water supply Make sure all fittings are tig...

Страница 17: ...r plugged pilot orifice Contact an authorized Delco service person Faulty pilot valve Contact an authorized Delco service person Faulty wiring Contact an authorized Delco service person Faulty ignitio...

Страница 18: ...______________________________________________________ ________________________________________________________________________________________________________ ________________________________________...

Страница 19: ...Page 19 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 1 Machine Layout...

Страница 20: ...Page 20 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 2...

Страница 21: ...tting 1 2 Female x 1 2 Male x x x x 47 54159A 1 Nipple Pipe 1 2 x 6 x x x x 48 56118A 1 Manifold Unloader 3 4 Brass x x x x 49 59404A 1 Valve Unloader x x 199126 1 Valve Unloader x x 50 170860 8 Washe...

Страница 22: ...Page 22 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 3...

Страница 23: ...96312 1 8 0 x 25 x x x 24 170014 1 Plug Pipe 1 2 Brass x x x x 25 170265 1 Tee 1 2 x 1 2 x 3 8 Galv x x x x x x x x 4 p m a l C 3 1 2 0 2 2 7 6 2 27 720271 1 Adapter 1 4 h to 1 4 mpt x x x x 28 170034...

Страница 24: ...Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 4...

Страница 25: ...x 3 4 x x x x 25 29661A 1 Panel Rear Control x x x x 26 171101 4 Nut Whiz Lock 3 8 16 x x x x 27 29667A 1 Bracket Control Panel x x x x 29 198605 1 Transformer 440V 240V 24V x x x x 29a 193775 1 Fuse...

Страница 26: ...DELCO Avenger 1000 3 NG LP Single Phase Pump Drawing...

Страница 27: ...g n i t c e n n o C 9 2 0 0 5 P I 6 2 27 IP 500 31 Socket Cap Screw M6 x 30 5 Ref Part No Description Qty Ref Part No Description Qty 1 r e v o C r a e R e s a c k n a r C 3 3 0 0 5 P I 8 2 1 e g u a...

Страница 28: ...DELCO Avengers 1000 3 NG LP Single Phase Electrical Schematic...

Страница 29: ...__________________________________________________ ________________________________________________________________________________________________________ ____________________________________________...

Страница 30: ...1111 E Lake Francis Dr Siloam Springs AR 72761 1 800 BUY DELCO...