Page 15
HOW TO CORRECT PROBLEMS IN THE MACHINE
Problem
Cause
Action
Oil is dripping
The oil seal is worn.
Contact an authorized Delco service person.
Chemical not
Chemical control valve
Tighten all fittings. Check for leaks in plastic
picking up.
leaking around fittings.
chemical lines.
Chemical control valve
Tighten jam nut. Replace valve.
leaking around stem.
Screens on chemical
Clean or replace.
suction lines stopped up.
Pop-off valve
Not adjusted properly.
Contact an authorized Delco service person.
leaking
Seat bad or worn.
Replace pop-off valve.
Nozzle stopped up or
Remove nozzle and clean. Turn hi-pressure
restricted in discharge.
pump on and flush lines, then replace nozzle.
The pump
The oil level is low.
Fill to the proper oil level with high quality SAE
overheats.
30-weight non-detergent oil.
The machine has been
Immediately press the gun release lever
running for an extended
to allow cool water to flow into the pump.
period of time with the trigger gun off.
Pressure excessive, rises too fast, and
Scale or dirt in coils
See "Preventative Maintenance" descaling of
pops off at relief valve
coils.
High pressure nozzle.
Remove nozzle at tip of gun and clean. Flush
There is/has been water in the oil and
The oil seal is worn.
Contact an authorized Delco service person.
water is dripping from under the pump.
The humidity is high.
Contact an authorized Delco service person.
Cracked plunger.
Contact an authorized Delco service person.
The plunger packing is
Contact an authorized Delco service person.
worn.
The plunger retainer
Contact an authorized Delco service person.
o-ring is worn.
Excessive vibration to gun and hose
Worn, clogged or defective
Contact an authorized Delco service person.
check valves in pump.
Restricted or under size nozzle.
Clean and or replace with proper size.
The pump is drawing air.
Contact an authorized Delco service person.
The motor will not start.
Power cord may not be connected.
Connect the power cord.
Switch may not be turned "ON",
Turn switch "ON".
Ground fault circuit
Reset the ground fault circuit interrupter.
interrupter did not reset.
The power cord may be
Contact a licensed electrician.
connected to a dead outlet.
May have a defective motor or switch.
Contact your authorized Delco dealer.
The thermal overload switch tripped.
Allow motor to cool, reset thermal switch.
Cause
Содержание Avenger 1000-3 LP
Страница 19: ...Page 19 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 1 Machine Layout...
Страница 20: ...Page 20 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 2...
Страница 22: ...Page 22 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 3...
Страница 24: ...Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 4...
Страница 26: ...DELCO Avenger 1000 3 NG LP Single Phase Pump Drawing...
Страница 28: ...DELCO Avengers 1000 3 NG LP Single Phase Electrical Schematic...
Страница 30: ...1111 E Lake Francis Dr Siloam Springs AR 72761 1 800 BUY DELCO...