Installation Manual
Festoon Systems for I-Beams
Program 0314
MAL0300-0001-EN
www.conductix.com
translated document
page 32 of 56
6.3.4
Fitting round cables
WARNING!
Risk of fire!
Risk of fire if undersized cables are used!
Therefore:
- The required cable cross-sections must be adhered to.
WARNING!
Danger due to improper cable installation!
Incorrect arrangement of the cables in the cable bundles and the loop may result in cable damage and
electric shocks.
Only use qualified electricians to connect up the cables.
Check the cables regularly for signs of wear or damage.
The cable configuration designed for the festoon system must be adhered to. The following rules are recommended:
-
When using cable trolleys with multiple cable support, the heaviest cables are to be placed on the uppermost cable clamp.
-
In the case of multilevel cable trolleys, the cables of the respective upper cable holders must be laid with a little less length than
the cables of the underlying cable holders.
-
The screws of the cable holders must be screwed tight enough so that thin cables are not pulled through during operation, but
the cables are not damaged by excessive clamping.