AGW–4015/4025/4045
Installation & Operations Manual
EZ-1 portable ambient ozone analyzer by
EcoSensors, Inc. is recommended for use with
the AGW–4015/4025/4045.
EcoZone™ Model EZ-1 features:
a.
• Constantly monitors work environment
• O
3
concentration shown by a multi-
color display from green (safe) to yellow
(caution) to red (danger)
• No installation required
• Easily understood by non-technical
personnel
• Field work and "walk around" analyses
possible via power from internal
rechargeable batteries
• Compatible with EcoSensor VOC and O
3
sensing, monitoring, and control products
EcoZone™ Model EZ-1 specifications:
b.
• Range: 0.02-0.14 ppm O
3
• Bar graph display: normally green, yellow
at 0.05 ppm (caution), red at 0.1 ppm
(danger)
• Response time: with a few seconds of O
3
reaching the sensor
• Accuracy: within 20% in the 0.05-0.1 ppm
range
• Recommended calibration check annually
• Temperature Range: 18-37°C (65-100°F)
• Measurement principle: HMOS (Heated
Metal Oxide Semiconductor) sensor
• Size: 85 x 35 x 60 mm (3 1/4" x 1 3/8" x 2
3/8")
• Weight: 154 grams (6 oz.)
• Power Requirements: 12-24 volts DC
at 300-500 mA. AC adapters available
worldwide.
• Batteries: self-contained NiMH.
Approximately 2 hour capacity.
Recharged by AC adapter overnight.
Badge-Type Ambient Ozone Monitor
Shall measure the level of ozone present in the
1.
room where ozone equipment is located.
The ChromAir® System ozone badge
2.
(K&M Environmental P/N 380010-10; www.
kandmenvironmental.com; 1-800-808-2234)
may be used for personnel or area monitoring
for exposure times ranging from 5 minutes to
10 hours. For higher resolution, the ChromAir
ozone badge may be used in conjunction with
the ChromAir ozone color comparator.
ChromAir System features:
a.
• Constantly monitors work environment
• Accurate measurements
• Ease of use - requires minimal training
• Cost effective - offers the most
inexpensive air sampling solution
available
ChromAir System specifications:
b.
• Color change: blue to white
• Exposure range: 0.08–1.6 ppm•hr
• Max. sampling time: 10 hours
• Min. sampling time: 5 minutes
• Relative humidity range: 20% - 90%
• Face velocity range: 10-165 cm/sec
• Temp. range: 16°C - 30°C (61°F - 86°F)
• Light effect - sunlight: not recommended
• Light effect - visible: no effect
• Dimensions: 10.5 cm x 5.5 cm x 0.25 cm
• Weight: 11 g
• Refrigerated shelf life: 1 year
Other ambient ozone monitors are also available.
Contact DEL for further information.
OZONE IN WATER
The ozone concentration in water can be measured
in different ways.
Oxidation Reduction Potential (ORP) monitor
1.
measures the effective biocidal activity of
dissolved ozone in water in millivolts and can
be converted to mg/l (ppm).
NOTE: ORP
is an ineffective measurement of ozone
concentrations greater than about 0.5 ppm.
Dissolved Ozone monitors measure levels
2.
of dissolved ozone in water (mg/l or ppm).
The HACH Indigo Blue AccuVac high range
dissolved ozone test kit (DEL P/N 6-0116) is an
inexpensive colorimetric test. Electronic, in-line
dissolved ozone monitors are also available.
Contact DEL for further information.
7E-3. Ozone Detection Data Log
In addition to automatic chart recorders, operators
should log ozone monitor output. Record ozone
output data twice per shift (maximum 12 hour
shift). If system does not have an automatic chart
recorder, record data every 4 hours, regardless of
shift changes. (See Daily Data Log - Appendix A).
7F. First Aid Procedures
7F-1. General
First Action:
DO NOT PANIC.
1.
If exposure to gaseous ozone causes
2.
headaches or shortness of breath, immediately
remove the patient to a fresh air environment.
Содержание AGW Series
Страница 2: ......
Страница 7: ...3 AGW 4015 4025 4045 Installation Operations Manual 3A Tank Charging System ...
Страница 8: ...4 AGW 4015 4025 4045 Installation Operations Manual 3B Tank Cleaning System ...
Страница 9: ...5 AGW 4015 4025 4045 Installation Operations Manual 3C Spray System ...
Страница 15: ...11 AGW 4015 4025 4045 Installation Operations Manual 60 Hz Electrical Diagram ...
Страница 16: ...12 AGW 4015 4025 4045 Installation Operations Manual 60 Hz Electrical Diagram cont ...
Страница 17: ...13 AGW 4015 4025 4045 Installation Operations Manual 50 Hz Electrical Diagram ...
Страница 18: ...14 AGW 4015 4025 4045 Installation Operations Manual 50 Hz Electrical Diagram cont ...
Страница 25: ...21 AGW 4015 4025 4045 Installation Operations Manual APPENDIX A DAILY DATA LOG ...
Страница 26: ...22 AGW 4015 4025 4045 Installation Operations Manual ...
Страница 27: ...23 AGW 4015 4025 4045 Installation Operations Manual APPENDIX B EMERGENCY INFORMATION ...
Страница 28: ...24 AGW 4015 4025 4045 Installation Operations Manual ...
Страница 29: ...25 AGW 4015 4025 4045 Installation Operations Manual APPENDIX C SAFETY ...
Страница 35: ......