Side Termination
Consult battery string layout diagram for termination location.
1. Remove module bolts (3/8-16 x 1.25") from the module where
side termination is to be installed. If safety shield bracket is at
one of these locations, retain for later use.
2. Install plastic side terminal bracket in location where bolts
were removed in previous step. Use 3/8-16 x 4.50" bolts. Bolts
should be installed loosely for future adjustments. Replace
safety shield bracket at same location from previous step.
SLEEVE
SPACER
SLEEVE
SPACER
4. Install side terminal connector to battery posts using 1/4- 20
bolts. Bolts should be installed loosely for future adjustments.
3.
The side terminal may be located at the bottom module. Slot
in lower arm of side terminal bracket slips over tab in base
plate. The upper side terminal bracket connection should be
attached as called out in previous section.
1CU / 2CU CONNECTOR PACKAGE
(single connector)
Review the “Connector Packages” chart (pg b.8) to ensure