Install/Activate tamper switches
The proxSafe flexx is equipped with two different tamper switches.
The right internal tamper switch (a) in picture 1 below) is connected to the input „Tamper
Wall“ on the flexx backplane PCB. It has a small metal strap used as a wall contact (see
picture below). This wall contact will initiate an internal alarm in case of a forced removal
from the wall. This alarm case consists of a message within the connected software system
(terminal/network PC), the red LED on top of the flexx will be turned on (only if operated
with proxSafe terminal; see also bottom note in 3.12 „Connect LEDs“) and another red
LED on the flexx backplane PCB itself will be turned on as well.
Note:
Due to connection to the internal power supply of the backplane PCB this tamper
alert will naturally fail to report any sabotage actions in case of a (forced)
disconnection from the power supply.
The left external tamper switch (b) in picture 1 below) is independent (potential-free) from
the flexx software and the flexx power supply. It is connected to a second small metal strap
also used as a wall contact (see same picture below). This external tamper switch can be
connected using the provided three pole connector (with 6.3 mm flat blade connectors). In
case of any removal from the wall this contact will release a signal, which can be used to
initiate an alarm in an external monitoring system (i.e. alarm system).
There is another input on the backplane PCB called „Tamper Service“. This contact is
normally bridged. If connected to an magnetic switch (optional) at the service door, this
tamper alert can also be used to report any (unauthorized) access to the flexx service door
within a software system (terminal/network PC).