12
the fuel in the burner. Power shutdown will also result in damping a
stove after fuel in the burner will be burnt.
If it is necessary to quickly damp a flame you should charge the furnace
chamber with dry sand or ash after power supply shutdown. It is not
allowed to damp a flame by pouring it with water because it may dam-
age components of the equipment.
After a longer break in the equipment’s operation, you
should check the flow capacity of the flue.
6.2.4.
POWER FAILURE DURING OPERATION
Fans and feeder will stop operation in case of power failure during
stove operation. Fuel dose in the burner should be burnt-out and flue
gas removed by a chimney draught. This will ensure safe shutdown of
the stove. Apply damping (chapter 6.2.3). If necessary (lack of suitable
draught).
7.
CLEANING AND MAINTENANCE
All operations related to cleaning of all components
should be carried out when the stove is completely
cold. It is required to use protective gloves.
It is a good practice to ensure good ventilation of the
room during the cleaning of the fireplace.
7.1.
BASIC OPERATIONS AND CLEANING BY THE USER
Any service and maintenance works are to be carried out with meticu-
lous care and only by adults familiarized with this manual. The dry stove
should not be cleaned in the presence of children.
Any service and maintenance works are to be carried
out with meticulous care and only by adults familiarized
with this manual. The dry stove should not be cleaned
in the presence of children.
7.1.1.
CLEANING BEFORE EACH STARTING
Prior to every successive start-up of the equipment, the ash container
should be cleaned and emptied, handling the ash with due care. Re-
move ash-pan for this purpose and remove the remaining dust. Dust
can be removed using vacuum cleaner only if it is completely cold. Use
vacuum cleaner adapted to removing the particles of a specified size
for this purpose.
1.
Remove the ash-pan to outside. Empty the ash-pan
2.
Remove the dust from ash-pan recess.
Re-install the ash container below the grate after the cleaning, making
sure that its position is correct.
7.1.2.
EVERY DAY SERVICE
Burner inspection - check whether the openings in burner bottom
have proper flow capacity. If they are blocked then you should
remove the burner from the recess and clean the openings using
a poker, then remove ash using a vacuum cleaner;
1.
Lift the burner, then take out the burner.
2.
Clean opening on bottom and sides of the burner.