Influence of the parameter setting CT.TEL on the I.TEL: contact
CT.TEL I.TEL:
C
contact closed
C
contact open
OPEN
ANTIFR
The mode selected on the boiler is active.
The antifreeze mode is active on all boiler circuits.
0/1 A
The antifreeze mode is active on the circuit
concerned.
The mode selected on the circuit is active.
0/1 B
The antifreeze mode is active on the circuit
concerned.
The mode selected on the circuit is active.
0/1 A+B
The antifreeze mode is active on the circuits
concerned
The mode selected on the circuits is active
0/1 C
The antifreeze mode is active on the circuit
concerned.
The mode selected on the circuit is active.
0/1 A+C
The antifreeze mode is active on the circuits
concerned
The mode selected on the circuits is active
0/1 B+C
The antifreeze mode is active on the circuits
concerned
The mode selected on the circuits is active
0/1 A+B+C
The antifreeze mode is active on the circuits
concerned
The mode selected on the circuits is active
0/1 DHW
The antifreeze mode is active for the DHW circuit. The mode selected on the DHW circuit is active.
0/1 A+DHW
The antifreeze mode is active on the circuits
concerned
The mode selected on the circuits is active
0/1 B+DHW
The antifreeze mode is active on the circuits
concerned
The mode selected on the circuits is active
0/1 A+B+DHW
The antifreeze mode is active on the circuits
concerned
The mode selected on the circuits is active
0/1 C+DHW
The antifreeze mode is active on the circuits
concerned
The mode selected on the circuits is active
0/1 A+C+DHW
The antifreeze mode is active on the circuits
concerned
The mode selected on the circuits is active
0/1 B+C+DHW
The antifreeze mode is active on the circuits
concerned
The mode selected on the circuits is active
0/1 AUX
4
The
M
AUX outlet on the connection terminal
block is not active.
4
The boiler operates with a set point
temperature as a function of the outside
temperature.
4
The
M
AUX outlet on the connection terminal
block is active.
4
The boiler operates at a set point temperature
equal to
BOILER MAX
.
5.5.3.
Naming the circuits and generators
1. Access the installer level: Press key
-
for around 5 seconds.
2. Select the menu
#NAMES OF THE CIRCUITS
.
4
Turn the rotary button to scroll through the menus or
modify a value.
4
Press the rotary button to access the selected menu
or confirm a value modification.
¼
For a detailed explanation of menu browsing, refer
to the chapter: "Browsing in the menus", page 49
1
1
2
2
r
c
STD
(
'
t
v
0
2
4
6
8
10
12
14
16
18
22
24
20
p
b
AUTO
x c
r
j
M
g
m
SUNDAY 11:45
5"
TEMP.: 68°
C002235-F-04
MCA 25/28 BIC
5. Commissioning
15/06/12 - 300022159-001-01
61