Code Faults
Cause
of the
fault
Description
Checking / solution
L16
PARASIT FLAME
PCU
Detection of a parasite flame
Ionization current present when there should not be a
flame
Ignition transformer defective
4
Check the ionization/ignition electrode
Gas valve defective
4
Check the gas valve and replace if necessary
The burner remains very hot: CO
2
too high
4
Set the CO
2
L17
VALVE FAIL
PCU
Problem on the SU PCB
Bad connection
4
Check that the SU PCB is correctly in place
SU PCB faulty
4
Inspect the SU PCB and replace it if need be
L34
FAN FAILURE
PCU
The fan is not running at the
right speed
Bad connection
4
Check the wiring between the PCU PCB and the
fan
Fan defective
4
Check for adequate draw on the chimney
connection
4
Replace the fan if need be
L35
BACK>BOIL FAIL
PCU
Flow and return reversed
Bad connection
4
Check that the sensor has been correctly fitted
Sensor fault
4
Check the Ohmic value of the sensors
4
Replace the sensor if necessary
Water circulation direction reversed
4
Check the circulation (direction, pump, valves)
L36
I-CURRENT FAIL
PCU
The flame went out more than
5 times in 24 hours while the
burner was operating
No ionization current
4
Purge the gas supply to remove air
4
Check that the gas valve is fully opened
4
Checking the gas supply pressure
4
Check the operation and setting of the gas valve
unit
4
Check that the air inlet and flue gas discharge flues
are not blocked
4
Check that there is no recirculation of flue gases
L37
SU COM.FAIL
PCU
Communication failure with the
SU PCB
Bad connection
4
Check whether the SU PCB has been correctly
fitted into the connector on the PCU PCB
4
Change the SU PCB
L38
PCU COM.FAIL
PCU
Communication failure
between the PCU and SCU
PCBs
Bad connection
4
Check the wiring between the PCU and SCU PCBs
4
Run an
AUTODETECTION
in the menu
#CONFIGURATION
SCU PCB not connected or faulty
4
Replace the SCU PCB
8. Troubleshooting
MCA 25/28 BIC
102
15/06/12 - 300022159-001-01
Содержание Innovens MCA 25/28 BIC
Страница 7: ...15 06 12 300022159 001 01 5 ...
Страница 114: ...9 2 1 Casing EV 119526 1 1 T001498 B 1001 1002 1006 9 Spare parts MCA 25 28 BIC 112 15 06 12 300022159 001 01 ...
Страница 122: ...9 Spare parts MCA 25 28 BIC 120 15 06 12 300022159 001 01 ...
Страница 123: ......