Parameters
Description
Factory setting
Customer setting
HP062
Cost of peak time electricity
Can be set from 1 to 250 (x € 0.01/kWh)
13
HP063
Cost of off-peak electricity
Can be set from 1 to 250 (x € 0.01/kWh)
9
HP064
Cost of fossil energy (oil or gas) - price per litre or per m
3
Can be set from 1 to 250 (x € 0.01/kWh)
90
AP103
Display language
AP104
Display contrast
AP105
Temperature display unit (°C or °F)
°C
6.1.4 PCB parameters for the PCB + sensor kit for circuits with
mixing valve
Certain parameters are displayed:
according to certain system configurations,
according to the options, circuits or sensors actually connected.
Tab.17 List of parameters accessible to the user
Parameters
Description
Factory setting
Customer setting
AP073
SUMMER / WINTER set point switch:
Can be set from 15 to 30°C
Set to 30.5°C = function deactivated
22°C
AP074
SUMMER override:
0 = OFF
1 = ON
0
CP010
Heating water flow temperature set point for the area heated
Can be set from 7 to 100°C.
40°C
CP040
Post-operation time of the generator pump
Can be set from 0 to 20 minutes
4 minutes
CP071
Room temperature set point in reduced mode
Can be set from 5 to 30°C.
16°C
CP072
Room temperature set point in comfort mode
Can be set from 5 to 30°C.
20°C
CP320
Circuit operating mode
0 = Timer program
1 = Manual
2 = Frost protection
0
CP350
Not available on this version
CP360
Not available on this version
CP540
Swimming pool water temperature set point
Can be set from 0 to 39°C
Set to 0: frost protection operation
20°C
CP570
Not available on this version
6.1.5 COUNTERS / TIME PROG / menus CLOCK
This menu contains the following sub-menus:
COUNTERS
TIME PROG : timer program
CLOCK
6 Settings
36
MIV-4