Measure
ment type
Unit
AWHP 4
MR
AWHP 6
MR-2
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Coefficient
of perform
ance (COP)
3.32
2.97
3.46
3.20
3.20
3.27
3.27
Absorbed
electrical
power
kWe
1.13
1.08
1.53
3.19
3.19
3.94
3.94
Tab.6
Cooling mode: outside air tempe35°C, water temperature at the 18°C. Performances in accordance with
EN 14511-2.
Measure
ment type
Unit
AWHP 4
MR
AWHP 6
MR-2
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Cooling out
put
kW
3.84
4.69
7.90
11.16
11.16
14.46
14.46
Energy effi
ciency ratio
(EER)
4.83
4.09
3.99
4.75
4.75
3.96
3.96
Absorbed
electrical
power
kWe
0.72
1.15
2.00
2.35
2.35
3.65
3.65
Nominal
amperage
A
3.40
5.43
9.40
11.05
3.68
17.15
5.71
Tab.7
Common specifications
Measure
ment type
Unit
AWHP 4
MR
AWHP 6
MR-2
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Total dy
namic head
at nominal
flow rate
kPa
58
49
29
11
11
35
35
Nominal air
flow rate
m
3
/hour
2100
2100
3300
6000
6000
6000
6000
Power volt
age of the
outdoor unit
V
230
230
230
230
400
230
400
Start-up
amperage
A
5
5
5
5
3
6
3
Maximal
amperage
A
13
13
19
29.5
13
29.5
13
Acoustic
power - In
side
(1)
dB(A)
52.9
52.9
53.3
53.3
53.3
53.3
53.3
Acoustic
power -
Outside
(1)
dB(A)
62.4
64.8
65.2
68.8
68.8
68.5
68.5
Acoustic
pressure
(2)
dB(A)
41.7
41.7
43.2
43.4
43.4
47.4
47.4
Refrigerant
fluid R410A
kg
2.1
2.1
3.2
4.6
4.6
4.6
4.6
Refrigera
tion connec
tion (Liquid/
Gas)
inch
1/4 - 1/2
1/4 - 1/2
3/8 – 5/8
3/8 – 5/8
3/8 – 5/8
3/8 – 5/8
3/8 – 5/8
3 Technical specifications
7623755 - v02 - 03072015
MIV-4
17