Product name
MIV-4
AWHP 11 MR-2
MIV-4
AWHP 16 MR-2
Seasonal space heating energy efficiency under
average conditions
ƞ
s
%
132
130
Seasonal space heating energy efficiency under
colder conditions
ƞ
s
%
113
113
Seasonal space heating energy efficiency under
warmer conditions
ƞ
s
%
167
161
Declared coefficient of performance or primary en
ergy ratio for part load at indoor temperature 20 °C
and outdoor temperature
T
j
T
j
= -7 °C
COPd
-
1.82
1.88
T
j
= +2 °C
COPd
-
3.43
3.33
T
j
= +7 °C
COPd
-
4.54
4.34
T
j
= +12 °C
COPd
-
6.24
5.82
T
j
= bivalent temperature
COPd
-
1.45
1.54
T
j
= operation limit temperature
COPd
-
1.45
1.54
Operation limit temperature for air-to-water heat
pumps
TOL
°C
-10
-10
Heating water operating limit temperature
WTOL
°C
60
60
Electrical power consumption
Off mode
P
OFF
kW
0.009
0.009
Thermostat-off mode
P
TO
kW
0.049
0.049
Stand-by
P
SB
kW
0.013
0.013
Crankcase heater mode
P
CK
kW
0.055
0.055
Supplementary heater
Rated heat output
(24)
Psup
kW
0.0
0.0
Type of energy input
Electricity
Electricity
Other characteristics
Capacity control
Variable
Variable
Sound power level, indoors - outdoors
L
WA
dB
53 – 69
53 – 69
Annual energy consumption under average con
ditions
Q
HE
kWh
3783
5184
Annual energy consumption under colder condi
tions
Q
HE
kWh
3804
5684
Annual energy consumption under warmer con
ditions
Q
HE
kWh
2580
4120
Rated air flow rate, outdoors for air-to-water heat
pumps
—
m
3
/h
6000
6000
Declared load profile
L
L
Daily electricity consumption
Q
elec
kWh
4.816
4.816
Annual electricity consumption
AEC
kWh
968
968
Water heating energy efficiency
ƞ
wh
%
106.00
106.00
Daily fuel consumption
Q
fuel
kWh
0.000
0.000
Annual fuel consumption
AFC
GJ
0
0
(1) The rated heat output
Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementa
ry heater
Psup is equal to the supplementary capacity for heating sup(Tj).
(2) If
Cdh is not determined by measurement, the default degradation coefficient is Cdh = 0.9.
3 Technical specifications
7623755 - v02 - 03072015
MIV-4
21