Dedicated Micros HyperSense Скачать руководство пользователя страница 4

Dedicated Micros ©2008

ANPR

RF Interference warning

This is a class A product. In a domestic environment this product may cause radio frequency 

interference, in which case the user may be required to take adequate measures.

Product Safety

WARNING

•  Installation and servicing is only to be carried out by suitably qualified and experienced personnel 

and should conform to all local codes.

•  Only power low voltage cameras from the provided power supply. Use only a Class 2 power supply 

with a minimum current of 0.5 amps and the wiring as specified in the National Electrical Code 

ANSI/NFPA 70.

This camera range is designed for use in general purpose CCTV applications and has no other 

purpose.
Only operate your camera between the temperatures of -10°C and +40°C. This low voltage camera 

must be powered with either a 12V DC or a 24V AC power supply. Do not operate your camera 

outside its specified power supply range.

FCC CLASS B REGULATORY NOTICE

This device complies with part 15 of the FCC Rules. Operation is subject to the following two 

conditions: (1) This device may not cause harmful interference, and (2) this device must accept any 

interference received, including interference that may cause undesired This equipment has been 

tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC 

Rules. These limits are designed to provide reasonable protection against harmful interference in 

a residential installation. This equipment generates uses and can radiate radio frequency energy 

and, if not installed and used in accordance with the instructions, may cause harmful interference to 

radio communications. However, there is no guarantee that interference will not occur in a particular 

installation. If this equipment does cause harmful interference to radio or television reception, which 

can be determined by turning the equipment off and on, the user is encouraged to try to correct the 

interference by one or more of the following measures:
 

Reorient or relocate the receiving antenna.

 

Increase the separation between the equipment and receiver.

 

Connect the equipment into an outlet on a different circuit different to the receiver.

 

Consult the dealer or an experienced radio/TV technician for help.

 

Modifications not expressly approved by the manufacturer could void the user’s authority to 

 

 

operate the equipment under FCC rules.

Содержание HyperSense

Страница 1: ...HyperSense ANPR Camera Installation Manual www dedicatedmicros com...

Страница 2: ...scribed herein without prejudice Contents Introduction 3 Components supplied 6 Installing the Camera 7 Mounting 9 Electrical Connections 10 Adjusting FOV and Focus 11 Configuring the Unit Intelligent...

Страница 3: ...dditional overview camera fitted would be used for recording images of the vehicle for verification or evidential purposes whilst CamVu versions of the HyperSense camera can be configured to carry out...

Страница 4: ...interference and 2 this device must accept any interference received including interference that may cause undesired This equipment has been tested and found to comply with the limits for a Class B di...

Страница 5: ...EMC Standard Residential Commercial and Light Industry EN 61000 3 3 Limitations of voltage changes fluctuations and flicker in public low voltage supply systems for equipment with rated current up to...

Страница 6: ...ponents Supplied 1 x DM HyperSense ANPR Camera IP66 housing with pre wired cabling 1 x DM HyperSense ANPR Manual 1 x 3mm A F Allen Key 1 x 5mm A F Allen Key 1 x Spanner Additional components for analo...

Страница 7: ...ling the camera ensure that it can capture the whole plate taking into account vehicles which may have their number plates positioned off centre To assist in directing any vehicles into the field of v...

Страница 8: ...ely identified This could lead to chaos at the entrance to a car park with an ANPR controlled barrier each rush hour Contingencies for such scenarios must be identified developed and be made available...

Страница 9: ...efore mounting on wall Use appropriate wall fixings to support the housing and camera B B B B To convert the housing from wall mounted to ceiling mounted orientation Remove 2 off fixings C rotate brac...

Страница 10: ...s Cat5 cable with single RJ45 plug Power Cable for installer termination into appropriate 12VDC 1A 24VAC 500mA PSU NOTE The HyperSense ANPR camera housing must be earthed by connecting the earth wire...

Страница 11: ...e housing needs to be opened to access the adjustment levers The following procedure should be followed 1 Remove the 6 off M5 x 20 socket head screws from the back plate using a 4mm A F long series ba...

Страница 12: ...network and a PC or laptop connected to the same network running NetVu ObserVer to enable fine focus Models that incorporate the overview camera can be adjusted by setting the overview image and then...

Страница 13: ...l attempt to contact the DHCP server every time it starts up If for any reason a DHCP server cannot allocate an IP address to the unit the camera will use a default IP address 169 254 6 10 Note Always...

Страница 14: ...Mozilla Firefox 6 12 2 Type the IP address of the unit into the address bar 3 The first Menu page will be displayed 6 13 The other configuration menus are accessible via the links on the left hand si...

Страница 15: ...allocated to the overview camera if fitted Note Camera 1 and Camera 2 Names will be recognised by any NetVu Connected device that views it ie NetVu ObserVer NetVu Console SD DV IP Range and HighVu and...

Страница 16: ...nit was installed on a DHCP network this will display the IP address of the DHCP server allocated on power up of the unit DHCP Subnet If the unit was installed on a DHCP network this will be the subne...

Страница 17: ...tely estimated This sets the limits at which the software will try and recognise a plate typically 10000 Min Plate size pixels Once the FOV and Focus have been set the Minimum plate size that can be d...

Страница 18: ...r another This can be used to generate alarm events on the DVR and send a PTZ camera to a preset to record the entry Camera Preset This parameter is the preset on a PTZ camera to be associated with AN...

Страница 19: ...ros 2008 19 ANPR Connections This page shows the IP addresses of machines currently connected to the camera via the network IP Addresses A list of up to four IP addresses connected to the camera will...

Страница 20: ...Dedicated Micros 2008 20 ANPR Reset This page allows the camera to be restarted remotely Reset System...

Страница 21: ...Dedicated Micros 2008 21 ANPR Camera Dimensions Overall Dimensions All dimensions in millimetres 230 150 140 332 451 95 Mounting Template 6 5 50 8 19 95 95 6 5 23 5...

Страница 22: ...ipaddress replacing ipaddress with the ip address of the unit From the same dos prompt Type dm at the username prompt Type telnet at the password prompt Type devcopy a web zip flash web zip Type CW0 d...

Страница 23: ...dows click on Start Run and type cmd in the dialog box that opens then click OK This opens up a dos window Type cd to get to the c prompt Type cd c hypersense or insert the local folder holding the do...

Страница 24: ...camera is as follows 1 5 6 9 RS232 Connectivity Pin Description Desc 1 Data Carrier Detect DCD 2 Receive Data RX 3 Transmit Data TX 4 Data Terminal Ready DTR 5 Ground GND 6 Data Set Ready DSR 7 Ready...

Страница 25: ...Dedicated Micros 2008 25 ANPR Notes...

Страница 26: ...Dedicated Micros 2008 26 ANPR Notes...

Страница 27: ...P 23 Installing the Camera 7 Intelligent IP Analogue ANPR with Overview Camera connections 10 Intelligent IP ANPR Camera connections 10 Intelligent IP Camera 10 Introduction 3 Locating the unit IP add...

Страница 28: ...nt Place Suite 100 Chantilly Virginia 20151 USA Dedicated Micros Australia PTY 5 3 Packard Avenue Castle Hill NSW 2154 Australia Dedicated Micros Asia PTY 16 New Industrial Road 03 03 Hudson Techno Ce...

Отзывы: