MDEK1001 Kit User Manual
© Decawave 2017
OP-MDEK1001-System-User-Manual-1.0
Page 34
8 L
OGGING
D
ATA VIA THE
USB
P
ORT
Tag location data can be logged using a USB connection instead of using the Android
application.
Note also that the PC terminal can be used to configure the anchors and tags
– the Android
application is not necessarily needed.
8.1 Instructions
1. Setup the anchors and tags network via the Android application (see section 7)
2. Download and install the J-Link software pack from Segger
https://www.segger.com/downloads/jlink/#J-
LinkSoftwareAndDocumentationPack
3. Download and install a common PC terminal program e.g. Tera Term
http://download.cnet.com/Tera-Term/3000-2094_4-75766675.html
4. Connect the tag to the PC via USB cable
5.
Open the device manager to identify what com port is assigned to the Tag, in this
case COM20
6.
Once the com port has been identified open up Tera Term. Select the appropriate
COM port as shown, and set the terminal baud rate to 115200. The tag should now
be connected.